T5000EN
rev.0105
Video Kit
digital installation
Stadio Plus
golmar@golmar.es
Instructions manual
www.golmar.es
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis.
Golmar reserves the right to make any modifications without prior notice.

Advertisement

Table of Contents
loading

Summary of Contents for golmar Stadio Plus T5000EN

  • Page 1 Stadio Plus golmar@golmar.es Instructions manual www.golmar.es Golmar se reserva el derecho a cualquier modificación sin previo aviso. Golmar se réserve le droit de toute modification sans préavis. Golmar reserves the right to make any modifications without prior notice.
  • Page 2: Table Of Contents

    Always use RG-59 or RG-11 coaxial cables. Never use coaxial antenna cable. In In case of two ways systems it will be only necessary to program the monitor installations no longers than 100m., Golmar RAP-5130 cable can be used. which will be called through the left push button.
  • Page 3: Door Panel Installation

    DOOR PANEL INSTALLATION DOOR PANEL INSTALLATION mbedding box positioning. ssembling the EL500 microprocessed circuit. The EL500 circuit is to be assembled on the top of the embedding box. Insert the circuit in the top flanges of the embedding box (1). Push-in the circuit in the bottom flanges (2) by pressing the pcb board.
  • Page 4 DOOR PANEL INSTALLATION DOOR PANEL INSTALLATION Coming from previous page escription of the configuration escription of the configuration dip jumpers. switch. Set to ON the switch number 2 for monitor or telephones The JP1, JP2, JP3 and JP4 configuration jumpers programming.
  • Page 5: Power Supply Installation

    DOOR PANEL INSTALLATION POWER SUPPLY INSTALLATION lace the nameplate labels. nstalling the FA-805 power supply. The power supply must be installed in a dry and 3,5 x 50 protected place. It's recommended to protect DIN-7971 the power supply by using a thermo-magnetic Open the label holder.
  • Page 6: Platea Plus Monitor

    MONITOR DESCRIPTION MONITOR DESCRIPTION escription of the Platea Plus unction push buttons. monitor. On-Off push button. After any monitor reset and during the next 45 seconds, all the monitor functions will be disabled, with the exception of call reception. 0000000000 Monitor Nº...
  • Page 7: El561 Module

    MONITOR ADJUSTMENTS MONITOR CONNECTOR DESCRIPTION L561 module for video escription of the RCPL-Plus inst a llations with twisted pair monitor connector. The monitors included in kits /SC come with the EL561 module plugged in the CN4 connector, that's placed in the monitor base. NOTE: on this type of installations the EL560 module must be plugged in the EL500 microprocessed circuit (page 6).
  • Page 8: Monitor Installation

    MONITOR INSTALLATION MONITORS PROGRAMMING ix the monitor connector to the rogramming the wall. monitors. Avoid to place the monitor near to heating sources, Set to ON the switch number 2 of the configuration dip switch, that's in dusty locations or smoky environments. accessible by opening the terminal connector protection cover.
  • Page 9: Description

    TELEPHONE DESCRIPTION TELEPHONE DESCRIPTION escription of the T-940 Plus erminal connector description. telephone. – positive, ground. A , D : audio, digital communication. Telephone handset. INT : intercom. Speaker grille. SA : auxiliary calling device output. Microphone hole. HZ- : door bell push button input.
  • Page 10: Programming

    TELEPHONES PROGRAMMING INSTALLATION DIAGRAMS rogramming the ush buttons telephones. wiring. Connect the push buttons in the CN2 connector terminal Set to ON the switch number 2 of the configuration dip switch, that's of the EL500 circuit as shown. Connect the CP terminal accessible by opening the terminal connector protection cover.
  • Page 11 INSTALLATION DIAGRAMS ne or several accesses with coaxial cable. Cascade installation example. Remove the jumper from the CN4 connector in all the monitors (see page 11), except on the one where the video cable finishes (don't uses Malla Malla the video output). Distributed installation example.
  • Page 12 INSTALLATION DIAGRAMS ne or several accesses with twisted pair. Cascade installation example. EL561 EL561 Remove JP1 jumper from all of the EL561 monitor modules (see page 11), except on the one where the twisted pair cable finishes (don't uses the video output). EL561 Distributed installation example.
  • Page 13: Optional Connections

    OPTIONAL CONNECTIONS OPTIONAL CONNECTIONS xternal lock release ntercom function. activation. The lock release can be activated at any moment Platea Plus monitor and T-940 Plus telephone have intercom facility between two units of the by using an external push button, that must be same apartment .
  • Page 14: Door Bell Push Button Connection25

    OPTIONAL CONNECTIONS OPTIONAL CONNECTIONS ctivation of a second onnexion of an a.c. lock FA-805 camera. release. As it is described on page 8, the lock release The use of a SAR-90 relay will be required to activate a second camera and an internal to be connected to the door panel modification on the monitor shall be done, as it's described on page 10.