Intruder alarm system
zone shutdown when 3 or 7 (use MASCAD to change this number) violations of the zone are detected. When
this parameter is enabled it specifies the number of violations of the same zone (triggered the siren, keypad
buzzer, and etc.), during a single armed period before the zone is automatically shutdown.
By default, the system is set to make a zone shutdown when 3 or 7 (use MASCAD to change this number)
Z01 Door
violations of the zone are detected. When this parameter is enabled it specifies number of violations of the same
Limit reports
Yes
14
zone reported to central monitoring station during a single armed period, before the zone is automatically
shutdown.
Used for perimeter protection. When special arming mode Pre-alarm is turned on and the pre-alarm zone is
Z01 Door
violated, the system will make an alarm without reporting to central monitoring station or to the user.
Pre - Alarm
No
15
With this attribute being set - a zone with Interior definition can't be violated when the system is armed in Night
Z01 Door
mode - the violation of this zone will trigger an alarm (except systems with PAS808M).
9
Armed in Night
No
Upon an alarm event occurrence the keypad KM24G informs the user of a security situation by playing voice
Z01 Door
files assigned to the zone (for example: Entry doors). The system user will hear the same voice announcement
9
Voice menu
[ENT]
in case of an alarm if the system will call him using a PSTN dialer or a GSM module. This menu allows to assign
up to 8 voice files from a suggested dictionary to each of the system zones. Press [ENT] to enter the menu.
Pulse counter determines the amount of beams that need to be crossed before the sensor will produce the
Z01 Door
alarm. Use [] or [‚] to change wireless detector BP2 pulse counter value: 2 pulses (the most sensitive mode),
Pulse counter
2 pulses
15
3 pulses, 4 pulses or SPEC (the less sensitive mode).
Use [] or [‚] to change wireless detector BP2 sensitivity: Normal or High.
Z01 Door
16
PIR sensitivity
Normal
PGM PROGRAMMING
The control panel has three built-in programmable trigger outputs (+BELL, -PGM, +PGM). System allows up to 16 programmable outputs.
Service Mode }System Setup }PGM outputs
It is recommended to give an appropriate name to the PGM. This name will be used by the system for SMS
O01 Siren
sending or for display on keypad's LCD screen and etc.
1
Name
Siren
PGM output address is a 3-digit number represented in MA_P format, where MA specifies a module address in
O01 Siren
the system and P specifies a PGM output terminal in the module board. Example: 00_1 - where 00 means
Address
00_1
2
control panel and 1 is the +BELL output. Other control panel outputs: -PGM/-PGM1 address is 00_2; +PGM/-
PGM2 address is 00_3.PGM output addresses on modules:
PGM output Definition describes what kind of system activity will activate the output. DON'T FORGET to assign
O01 Siren
zones, partitions and etc. to PGM'S output triggering source, otherwise the PGM will not work correctly.
3
Definition
Fire/Burglary
(emergency keys). Note: output also activates when zone or module tamper conditions are present (when the
system is armed).
Note: output also activates when zone or module tamper conditions are present (when the system is armed).
is activated until any of the selected zones remain violated.
active after the exit delay expires.
pulses). In case of an unsuccessful arming - the output activates for 5 pulses. After alarm clearing this output can
also be activated for a specific period of time.
for a specific period of time from the keypad.
requires a reset for these detectors the output will be switched off for a specific amount of time. This output will be
switched off each time after system arming and alarm clearing. This output can also be switched off from the
menu.
KM24/24A/24G:
EXM800:
Z2/PGM - MA_1.
Z8/K1 - MA_1;
Z2/K7 - MA_7.
Not used - unused PGM output should be programmed as Not Used.
Fire Alarm - output activates if an alarm occurs on the selected zone or module (emergency keys).
Fire/Burglary Alarm - output activates if fire or burglary alarm occurs on the selected zone or module
Burglary Alarm - output activates if burglary alarm occurs on the selected zone or module (emergency keys).
Tamper Alarm - output activates if tamper alarm occurs on the selected zone or module.
Technical Alarm - output activates if technical alarm occurs on the selected technical zone.
Selected Alarms - output activates if a selected type of alarm occurs on the selected partition.
Chime - output activates if the selected zone is violated (when the system is disarmed).
Zone Violation - output activates if the selected zone is violated. If Pulse length is 0 seconds, then the output
Bypass Status - output activates when a zone is bypassed and deactivates when the zone is reinstated.
System Trouble - output activates if any selected trouble is present.
Exit /Entry Delay Warning - output activates if an entry/exit delay is in progress in the selected partition.
Exit Delay/Arm Status - output activates during an exit delay and if selected partition is armed it will remain
Full Arm Status - output activates if all of the selected partitions are armed.
Notifications - output activates if the selected partition is being armed (1 pulse) or it is being disarmed (2
Power Supply - output can be used as a power supply for external devices.
Resettable Power Supply - output can be used as a power supply for external devices. It can be switched off
Fire Power Supply - output can be used as power supply for fire or smoke detectors. When the system
EXT116S:
Relay - MA_1.
...
Systems with KM24x, KM25 keypads
Programming manual
PWR20:
+BELL - MA_1;
PGM1 - MA_2;
PGM2 - MA_3.
Page 7