SECOLink MAS-800 Short User Manual

Intruder alarm system km20b, km20bt, km20gt keypad

Advertisement

Quick Links

Intruder alarm system
MAS-800
Pre-alarm indication
pre-alarm
Emergency keys
A
B
Functional keys
(F-keys)
C
F
This key is used for partition review,
also for marking all partitions or
selecting another element
(for example for User selecting)
Functional keys for quick and comfortable control of the system
The SECOLink Security system comes with a standard set of function keys (F - keys) that are described below. This allows
you to carry out your most frequently used functions by using only one or two buttons. This also allows you to avoid system
management via the Menu navigation. During the installation you can create
individual F - keys, which can be adapted for the needs of the protected building
and the user. To view the current list of F - keys, press
pressing
and
keys.
Ways of arming
The system can be armed by three ways: F-key, via Menu, entering PIN code. The system function which is controlled by
F-key can be called by pressing the F-key combination and
combination. When Arming is activated via Menu, it's necessary to mark the partitions, which will be armed (mark the
partitions with
or
"Away" mode.
Arming mode "Away" – A
This arming mode is used when you want to protect a premise, when nobody will be staying inside. After
arming, all zones will be protected. After using the door will be entry delay time for disarming. Arming:
F-key:
LCD indication:
PIN code:
via Menu:
Arming mode "Stay" – AA
This arming mode is used to protect a house, when we are staying at home (inside) and are waiting, that
somebody can come in. Interior zones aren't protected. After opening the door will be entry delay. Arming:
F-key:
LCD indication:
Via Menu:
Arming mode "Max Away" – AAA
This arming mode is used when we are leaving the premise for a long period(e.g. vacations). After arming,
all zones will be protected, entry delay is off, alarm will sound upon opening door. Arming :
F-key:
LCD indication:
Via Menu:
Forced Arming – F , AAAA
The arming mode, that allows to arm the system when the zones are violated or the sensor is broken. All
sensors, which were remained earlier, will be armed. After opening the entry/exit door the system will give
entry delay time. Arming:
F-key:
LCD indication:
Via Menu:
1
2
3
4
5
6
! !
! !
7
8
9
0
#
and confirm with
). When arming is activated by Entering PIN code, it will be armed in
ENT
for EU countries –
.
PIN:
ENT
, [Arming]
,
ENT
ENT
for EU countries –
, [Arming]
ENT
ENT
[PIN:],
A
A
A
ENT
, [Arming]
ENT
ENT
for EU countries –
, [Arming]
ENT
ENT
MAS-800 (KM20B, KM20BT, KM20GT keypad)
MAS-800 (KM20B, KM20BT, KM20GT keypad)
alarm
System's state
armed
LED indication
trouble
CLR
Main menu
navigation keys
ENT
This key is used for zone review,
also for marking the partitions and
other elements of the system
(for example for marking zone,
which'll be bypassed)
key, and then keep
F
or by pressing and holding the last letter/number of the F-key
ENT
,
, for non EU countries is available
A
ENT
PIN:
ENT
[All partitions]
, [PIN:]
ENT
, for non EU countries is available
A
A
ENT
PIN:
ENT
, [Stay]
, [PIN:]
ENT
.
PIN:
ENT
Max Away
, [
]
, [PIN:]
ENT
, for
F
ENT
PIN:
ENT
, [Forced Arming]
Date
Time
Status of the system: Entry Doors are open.
There are 4 partitions in system:
- the first partition is armed in the "Stay" mode,
- the second partition is armed in the "Night" mode,
- the third partition is armed in the "Max Away" mode,
- the fourth partition is armed in the "Away" mode.
Environment temperature
(for KM20BT, KM20GT)
Status of the system: SYSTEM IS ARMED
.
PIN:
ENT
, [Parts:]
PIN:
ENT
, [Parts:]
PIN:
ENT
non EU countries is available
, [PIN:]
.
ENT
PIN:
ENT
Short user manual
There is 1 partition in the
system. This partition isn't
armed and there is one
zone, which is violated.
F-key
F-key (the name)
.
A
ENT
.
A
A
ENT
.
ENT
.
ENT
.
F
ENT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAS-800 and is the answer not in the manual?

Questions and answers

NAJIH
April 15, 2025

Sir, i have a secolink MAS-800, i need a software programming. I search it in google but i did not find. Please send it to me. I have a default in panel keypad.

User image 67febe2c1328f
1 comments:
Mr. Anderson
April 15, 2025

The SECOLink MAS-800 allows software programming using function keys (F-keys), which can be customized during installation for specific needs. Programming can also be done via the Menu by entering PIN codes to access settings such as date and time, temperature correction, and user management.

This answer is automatically generated

Summary of Contents for SECOLink MAS-800

  • Page 1 Functional keys for quick and comfortable control of the system The SECOLink Security system comes with a standard set of function keys (F - keys) that are described below. This allows you to carry out your most frequently used functions by using only one or two buttons. This also allows you to avoid system management via the Menu navigation.
  • Page 2 Abort arming Abort arming For selecting, also for aborting arm procedure the system SECOLink has the For selecting, also for aborting arm procedure the system SECOLink has the For selecting, also for aborting arm procedure the system SECOLink has the...
  • Page 3: Emergency Keys

    MAS-800 (KM20B, KM20BT, KM20GT keypad) MAS-800 (KM20B, KM20BT, KM20GT keypad) Intruder alarm system Short user manual Emergency keys In order to call for a help (the premises must be secured by CMS) press at once two specific keys and hold them at least 1 second.
  • Page 4 The system is made in Lithuania, warranty term is 24 months. The manufacturer – company "Kodinis Raktas" declares, that product “SECOLink” complies with essential EU directive and EU standard EN 50131-1. See manufacturer’s web site: www.kodinis.lt for complete text of declaration.

Table of Contents

Save PDF