Hdd Led; Nic1 Led; Nic2 Led; Overheat Led - Supermicro X5DL8-GG User Manual

Supermicro x5dl8-gg motherboards: user guide
Table of Contents

Advertisement

HDD LED

The HDD LED (for IDE and SCSI
disk drives) connection is located
on pins 13 and 14 of JF1. Attach
the IDE hard drive LED cable to
these pins to display disk activity.
Refer to the table on the right for
pin definitions.

NIC1 LED

The NIC1 (LAN1) LED connection
is located on pins 11 and 12 of
JF1. Attach the NIC1 LED cable to
display network activity.
the table on the right for pin defini-
tions.

NIC2 LED

The NIC2 (LAN2) LED connection
is located on pins 9 and 10 of JF1.
Attach the NIC2 LED cable to dis-
play network activity. Refer to the
table on the right for pin defini-
tions.
Overheat LED (OH)
Connect an LED to the OH connec-
tion on pins 7 and 8 of JF1 to pro-
vide advanced warning of chassis
overheating. Refer to the table on
the right for pin definitions.
Refer to
2-9
Chapter 2: Installation
(IDE) HDD LED Pin
Definitions
(JF1)
Pin
Number
Definition
13
+5V
14
HD Active
NIC/LAN1 LED
Pin Definitions
(JF1)
Pin
Number
Definition
11
+5V
12
GN D
NIC/LAN2 LED
Pin Definitions
(JF1)
Pin
Number
Definition
9
+5V
10
GN D
Overheat (OH) LED
Pin Definitions
(JF1)
Pin
Number
Definition
7
+5V
8
GN D

Advertisement

Table of Contents
loading

This manual is also suitable for:

X5dlr-8g2

Table of Contents