AUTOMATIC ELECTRONIC DIAGNOSTICS
This water softener has a self-diagnostic function for
the electrical system (except input power and/or water
meter). The water softener monitors electronic
components and circuits for correct operation. If a
malfunction occurs, an error code appears in the
display.
While an error code appears in the display, all buttons
are inoperable except the PROGRAM button.
PROGRAM remains operational so the service
person can perform the Manual Advance Diagnostics,
see below, to further isolate the problem.
Procedure for removing error code from
display:
1. Unplug the power supply from electrical outlet.
2. Correct problem.
3. Plug the power supply back in.
4. Wait 8 minutes. The error code will return if the
problem was not corrected.
MANUAL ADVANCE DIAGNOSTICS
Use the following procedures to advance the water
softener through the regeneration cycles to check
operation.
Lift off the salt lid, remove the top cover by unlocking
the tabs in the back and rocking forward, to observe
cam and switch operation during valve rotation.
1. Press and hold PROGRAM for 3 seconds until
"000" shows in the display, then release.
2. The 3 digits indicate water meter operation as
follows:
000 (steady) = Soft water not in use, and no flow
through the meter.
Open a nearby soft water faucet.
000 to 140 (continual) = Repeats for each gallon

Troubleshooting

FIG. 36
of water passing through
the meter.
3. Symbols in the display indicate POSITION switch
operation (See Figure 37).
Switch is open
(Cam not rotating)
4. Use the RECHARGE button to manually advance
the valve into each cycle and check correct switch
operation.
NOTE: Be sure water is in contact with the salt, and
not separated by a salt bridge (See "Breaking
A Salt Bridge" section).
5. While in this diagnostic screen, the following
information is available and may be beneficial for
various reasons. This information is retained by the
computer from the first time electrical power is
applied to the electronic controller.
r
a. Press the
days this electronic control has had electrical
power applied.
s
b. Press the
of regenerations initiated by this electronic
control since the code number was entered.
6. Press and hold the PROGRAM button until the
model code ("L40P" for Model WHES40 or "L44P"
for Model WHES44) shows in the display. This
code identifies the softener model. If an incorrect
model code is displayed, the softener will operate
on incorrect configuration data.
7. To change the code number, press the
s
DOWN button until the correct code shows.
8. To return to the present time display, press the
PROGRAM button.
20
Switch is closed
(Cam rotating)
UP button to display the number of
DOWN button to display the number
r
FIG. 37
FIG. 38