Chapter 2: Server Installation
2-4

Installing the SuperServer 6023P-i into a Rack

This section provides information on installing the SuperServer 6023P-i
into a rack unit. If the 6023P-i has already been mounted into a rack,
you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack
units on the market, which may mean the assembly procedure will differ
slightly. The following is a guideline for installing the 6023P-i into a rack
with the rack rails provided. You should also refer to the installation
instructions that came with the rack unit you are using.

Identifying the Sections of the Rack Rails:

You should have received two rack rail assemblies with the SuperServer
6023P-i. Each of these assemblies consist of three sections: an inner
fixed chassis rail that secures to the 6023P-i (A) and an outer fixed rack
rail that secures directly to the rack itself (B). A sliding rail guide sand-
wiched between the two should remain attached to the fixed rack rail.
(See Figure 2-1.) The A and B rails must be detached from each other to
install.
To remove the fixed chassis rail (A), pull it out as far as possible - you
should hear a "click" sound as a locking tab emerges from inside the rail
assembly and locks the inner rail. Then depress the locking tab to pull
the inner rail completely out. Do this for both the left and right side rack
rail assemblies.
Figure 2-1.
Identifying the Sections of the Rack Rails
2-3