Sled1 (Scsi Led) Indicator; Power Supply Fail Header; Ipmb; Smb - Supermicro SUPERSERVER 6021H User Manual

Supermicro superserver 6021h servers: user guide
Table of Contents

Advertisement

SLED1 (SCSI LED)
Indicator
The SLED connector is used to
provide an LED indication of SCSI
activity. See the table on the right
for pin definitions.

Power Supply Fail Header

Connect a cable from your power
supply to the header labelled JP54
to provide warning of power sup-
ply failure. This warning signal is
passed through the PWR_LED pin
on JF1 to provide indication of a
power failure on the chassis.
This feature is only available when
using Supermicro power supplies.
See the table on the right for pin
definitions.

IPMB

An IPMB (Intelligent Platform Man-
agement Bus) connection is lo-
cated at JP70. Connect the appro-
priate cable here to utilize IPMI on
your system.

SMB

An SMB (System Management
Bus) connection is located at
JP71.
Connect the appropriate
cable here to utilize SMB on your
system.
S C S I L E D P in D e fin itio n s
P in
N umber
1
2
3
4
P o w e r S u p p ly F a il H ea d e r
P in D e fin itio n s (J P 5 4 )
P in
N umber
1
2
3
4
5-17
Chapter 5: Installation
(S L E D 1 )
D efinition
P ositive
N egative
N egative
P ositive
D efinition
P /S 1 F ail S ignal
P /S 2 F ail S ignal
P /S 3 F ail S ignal
R eset (from M B )