Operating and
installation instructions
REMKO LTE Eco series
Dehumidifier
LTE 50 Eco, LTE 60 Eco, LTE 80 Eco
0284-2021-02 Edition 1, en_GB
Read the instructions prior to performing any task!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LTE 50 Eco and is the answer not in the manual?

Questions and answers

Summary of Contents for REMKO LTE 50 Eco

  • Page 1 Operating and installation instructions REMKO LTE Eco series Dehumidifier LTE 50 Eco, LTE 60 Eco, LTE 80 Eco 0284-2021-02 Edition 1, en_GB Read the instructions prior to performing any task!
  • Page 2 Read these operating instructions carefully before commis- sioning / using this device! These instructions are an integral part of the system and must R454C always be kept near or on the device. Subject to modifications; No liability accepted for errors or mis- Refrigerant prints! Translation of the original...
  • Page 3: Table Of Contents

    Table of contents Safety and usage instructions......................4 1.1 General safety notes........................4 1.2 Identification of notes........................4 1.3 Personnel qualifications........................4 1.4 Dangers of failure to observe the safety notes................4 1.5 Safety-conscious working....................... 5 1.6 Safety instructions for the operator....................5 1.7 Safety notes for installation, maintenance and inspection work............
  • Page 4: Safety And Usage Instructions

    REMKO LTE Eco series Safety and usage instructions DANGER! This combination of symbol and signal word 1.1 General safety notes warns of a situation in which there is immediate danger, which if not avoided may be fatal or Carefully read the operating manual before com- cause serious injury.
  • Page 5: Safety-Conscious Working

    In particular, failure to observe the safety notes The units must not be transported while they may pose the following risks: are running. The units must only be transported when the The failure of important unit functions. condensate container is empty and the evapo- The failure of prescribed methods of mainte- rator is dry.
  • Page 6: Unauthorised Modification And Changes

    Do not operate units or components with plete and return the "certificate of warranty" to obvious defects or signs of damage. REMKO GmbH & Co. KG at the time when the The units may not be installed or operated in units are purchased and commissioned.
  • Page 7: Environmental Protection And Recycling

    1.12 Environmental protection and recycling Disposal of packaging All products are packed for transport in environ- mentally friendly materials. Make a valuable contri- bution to reducing waste and sustaining raw mate- rials. Only dispose of packaging at approved collection points. Disposal of equipment and components Only recyclable materials are used in the manufac- ture of the devices and components.
  • Page 8: Technical Data

    REMKO LTE Eco series Technical data 2.1 Unit data Unit type LTE 50 Eco LTE 60 Eco LTE 80 Eco Operating range, temperature °C 3 to 32 Operating range, humidity % RH 40 to 100 Dehumidification capacity max. l/day at 30 °C / 80% RH...
  • Page 9 Unit type LTE 50 Eco LTE 60 Eco LTE 80 Eco Dimensions Depth Width Height Height incl. transportation bracket Weight 38.5 40.0 45.0 EDP no. 618510 618610 618810 EDP no. Unit with condensate pump 618515 618615 618815 Contains greenhouse gas according to Kyoto protocol.
  • Page 10: Design And Function

    The use of REMKO air dehumidifiers With regard to energy consumption, air dehumidifi- Even if windows and doors are well insulated, cation has one distinct advantage: water and moisture are still capable of pene- trating thick concrete walls.
  • Page 11 Evaporation occurs on the surface = Transfer 10.4 of water vapour to the ambient air The air containing water vapour is constantly 13.8 circulated through the REMKO air dehumidifier. 12.9 18.2 The air is dehumidified and, slightly heated, leaves the unit in order to re-absorb water...
  • Page 12 REMKO LTE Eco series Functional principle of the air dehumidifier As it flows through or over the evaporator, the air stream is cooled to dew point. The water vapour con- denses, and is collected in a condensate trap from where it is drained off.
  • Page 13: Unit Description

    Energy must be supplied when liquid is converted The units may be used for the drying and dehumid- into a gas. This energy is designated as evapora- ification of areas such as: tion heat. It does not cause any increase in tem- New buildings, industrial buildings perature, but is required to convert a liquid into a Basements, storage rooms...
  • Page 14 REMKO LTE Eco series Fig. 5: Air dehumidification operating principle A: Dehumidified room air 3: Evaporator B: Moist room air 4: Compressor 1: Fan 5: Condensate container 2: Condenser...
  • Page 15: Assembly

    Assembly 4.1 Setting up the unit NOTES: For the best economic and safe use of the units, – Keep windows and doors closed! the following notes must be followed in full: – Keep at least 0.5 m away from walls. The units must be set up in an upright and –...
  • Page 16: Electrical Wiring

    REMKO LTE Eco series Electrical wiring 5.1 General notes Extensions to the connection cable may only be carried out by authorised electricians, sub- The units are operated with 220-240 V/50 Hz ject to the length of the cable, connected load...
  • Page 17: Commissioning

    Commissioning Starting the unit Start the unit as follows: Before commissioning the unit or if local require- ments dictate, the air-inlet grille and air-outlet grille Plug the unit's power plug into a properly must be checked for contamination. installed and fused mains socket (220-240 V/50 Hz).
  • Page 18 REMKO LTE Eco series Control and display panel: Fig. 8: Control panel ON / OFF key: If the humidity lies below the target humidity set (i.e.: rRH <-3%), the compressor and the fan After actuating the ON / OFF key whilst switched motor stop.
  • Page 19 Function or situation Segment display Power plug is plugged in, the unit is Current measured room humidity is displayed switched off The unit starts Current measured room humidity is displayed During the adjustment of the target room The target room humidity set is displayed humidity The current measured room temperature is Upon actuation of the ROOM TEMP.
  • Page 20 REMKO LTE Eco series If Tc is >50 °C and the compressor runs within 5 If the unit is switched off while the "FULL TANK" minutes, the unit switches off and the error code and "CHECK" indicators are illuminated, both indi- "E3"...
  • Page 21 Function table: Power plug Operating status: Unit Full tank Functions Defrost function inserted operating or in standby function Standby After the The unit 30 min. timer 30 mins. (no opera- starts expires if defrost timer (no opera- tion) function has tion) r RH >+4% Te<=1 °C...
  • Page 22: Condensate Removal

    REMKO LTE Eco series Condensate removal Depending on the air temperature and the relative humidity, condensed water will drip into the con- densate container either continuously or only during the defrosting phases. A float is located inside the condensate container.
  • Page 23 Unit operation with condensate pump (optional) The condensate tank with integrated pump has two magnetic contacts [E] on the rear to establish the electrical connection with the unit. If the unit is sup- plied with power, 12 V DC is continuously present at the contacts on the unit side.
  • Page 24 REMKO LTE Eco series NOTICE! If the condensate pump runs for an extended period of time, the condensate tank must be checked for contamination at regular intervals. Unit operation with a condensate tank without pump is possible at any time.
  • Page 25: Troubleshooting And Customer Service

    Troubleshooting and customer service The unit and components are manufactured using state-of-the-art production methods and tested several times to verify that they function correctly. However, if alarms should occur, please check the functions as detailed in the list below. Please inform your dealer if the unit is still not working correctly after all function checks have been performed! Operational malfunctions Malfunction...
  • Page 26: Shutdown

    REMKO LTE Eco series Display of error codes Error codes are displayed in the segment display [1]. Fig. 15: Segment display Error code description: Error code Error description Evaporator temperature probe (Te) defective Condensate temperature probe (Tc) defective Compressor runs within 5 minutes and the condenser temperature (Tc) > 50 °C E3 flashes Compressor runs over 5 minutes and the condenser temperature (Tc) >...
  • Page 27: Care And Maintenance

    Care and maintenance 10.1 Care and maintenance Cleaning the dust filter General notes NOTICE! Check the inlet and outlet grille and the dust filter for contamination on a regular basis. Regular care and maintenance is fundamental to a long service life and fault-free operation of the unit.
  • Page 28 REMKO LTE Eco series Cleaning the units Clean the evaporator fins, for example with a lukewarm soap solution (or similar). The unit housing must be opened to allow the inside of the unit to be cleaned and to provide access to electrical components.
  • Page 29: Maintenance Protocol

    10.2 Maintenance protocol Unit type: Unit number: -------------------------------- --------------------------------------- Unit cleaned - outside - Unit cleaned - inside - Fan blade cleaned Fan housing cleaned Condenser cleaned Evaporator cleaned Fan function checked Air-inlet grid with filter cleaned Unit checked for damage Safety devices checked All fastening screws checked Electrical safety check...
  • Page 30: Exploded View Of Unit And Spare Parts

    REMKO LTE Eco series Exploded view of unit and spare parts 11.1 Exploded view of the unit LTE 50/60/80 Eco We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
  • Page 31: Spare Parts List Lte 50/60/80 Eco

    11.2 Spare parts list LTE 50/60/80 Eco LTE 50 LTE 60 LTE 80 No. Designation Lock for sealing flap Air-inlet grille Dust filter Unit housing Control panel Filter grill, interior Evaporator fin package cpl. Top separating panel Transportation bracket Side covering, right Support frame Fan blade Engine mounting cpl.
  • Page 32 REMKO LTE Eco series LTE 50 LTE 60 LTE 80 No. Designation Wheel Wheel Triangular bracket Condensate tank fastening plate Base plate Compressor, cpl. Solenoid valve Coil for solenoid valve Housing cover Operating condenser On request by providing the serial number...
  • Page 33: Index

    Index Air dehumidification, description ... . 10 Operating sequence ..... 13 Automatic restart after power failure .
  • Page 34 REMKO LTE Eco series...
  • Page 36 REMKO QUALITY WITH SYSTEMS Air-Conditioning | Heating | New Energies Telephone +49 (0) 5232 606-0 REMKO GmbH & Co. KG Hotline within Germany +49 (0) 5232 606-0 Klima- und Wärmetechnik Telefax +49 (0) 5232 606-260 Im Seelenkamp 12 E-mail info@remko.de...

This manual is also suitable for:

Lte eco seriesLte 60 ecoLte 80 eco

Table of Contents