M800S/M80/E80 Series Connection and Setup Manual
7 Connection of Control Unit

7.9 Connecting with Skip Signal (Sensor)

Connect the skip signals to SKIP connector of the control unit.
Skip signals are used for processing high-speed signals. Always shield the cable.
Control unit
SKIP
(Note)
Connecting the skip signal cable to a wrong connector causes a damage on the control unit when turning ON
the skip signal power supply. Confirm the wiring before turning the power ON.
(1) Connection of skip signal cable
<0V connection at COM terminal>
Control unit
SI1
SI2
SI3
SI4
SI5
SI6
SI7
SI8
0V connection at COM terminal
IB-1501269-J
J100
SKIP
J100
2.35kΩ
2
12
3
13
7
17
8
18
COM
1,5,11,15
FG
COM
COM
SK0
SK1
SK2
SK3
COM
COM
SK4
SK5
SK6
SK7
Stabilized
power supply
24VDC(+)
0V
FG
246