Horizontal types of construction with mounting feet

1. Refer to any instructions for aligning the driven machine and those of the coupling
2. Align the motors with coupling output to the driven machine in such a manner that the
3. For the vertical positioning (x→0) place thin shims under the motor feet. The number of
4. When positioning the motor, ensure that a uniform axial gap (y→0) is maintained around
5. Fix the motor to the foundation. The choice of fixing elements depends on the foundation
5.5.2.3

Horizontal types of construction with flange

The standard flange is provided with a centering. The choice of fit for the mating flange on
the driven machine is the system manufacturer's or the plant operator's responsibility.
If the motor is not fitted with a standard flange, align the motor to suit the driven machine.
Procedure
The motor axis must be horizontal when it is lifted and the flange must be parallel to the
mating flange, so as to avoid seizing and stressing.
1. Grease the centering flange with assembly paste to make the process easier.
2. Screw three studs evenly apart into tapped holes around the driven machine flange. The
3. Position the motor so that its axis is aligned with that of the driven machine, but not yet
4. Move the motor fully up against the mating flange so that it is fully in contact.
5. Fix the motor using the flange fixing bolts, finishing by replacing the studs.
See also
Tightening torques for screw and bolt connections (Page 249)
1LE8 轴高 80 ... 355
操作说明, 11/2022, A5E52373573A
manufacturer.
center lines of the shafts are parallel with no offset. This ensures that no additional forces
affect their bearings during operation.
shims should be kept as low as possible, i.e. stack as few as possible. This also prevents the
motor being subjected to any stress/distortion.
the coupling.
and is the plant operator's responsibility.
Note
Motor expansion
When aligning, make allowance for the thermal expansion of the motor when the
temperature increases.
studs act as positioning aids.
quite touching. Advance the motor slowly towards the driven machine; advancing too
quickly risks damaging the three positioning studs.