WARNING
MOVING PARTS HAZARD
To reduce the risk of serious injury, including cuts, amputation of fingers by the agitator blades, and
splashing in the eyes or on the skin, always shut off the agitator (disconnect the air line from the agitator)
before you raise, check, or repair the agitator.
Startup
1. Make sure the needle valve (23) is closed.
2. Turn on the air supply, and connect the air line
coupler.
3. Using the needle valve (23) to adjust the agitator
speed, gradually increase the speed until you can
see through the inspection port movement in the
surface of the liquid, but do not increase the agitator
speed enough to create a vortex in the surface of
the liquid. If the surface begins to vortex, decrease
the agitator speed to prevent air entrainment.
NOTE: Always maintain moderate agitator speed, which
is approximately 50 rpm of the agitator blades.
Excessive agitator speed may cause vibration, foaming
of fluid, and increased wear on parts. Always agitate
fluid thoroughly before supplying it to the dispensing
equipment. Continue agitating fluid while the dispensing
equipment is being supplied.

Operation

Shutdown
To stop the agitator, close off the air supply with the
needle valve (23), or disconnect the air line coupler.
Keep the agitator upright. Do not lay it on its side or
upside down, or liquid may flow down the shaft and
into the gear reducer area.
CAUTION
308609 9