3.23 REPLACING MANIFOLD SEALS
The operations described below must be performed after having removed the voltage from the
appliance.
After checking the integrity of the seals, proceed as follows if they need to be replaced:
Victrix Tera V2 24 Plus EU
1. Remove old seals.
2. Place the module gasket (1) radially on the edge of the condensation module flange (2).
3. Make sure that the gasket tab with number 4 printed on it is positioned in its seat on the module flange, identified by the number 4.
Every time the manifold is opened, the condition and integrity of the ceramic fibres must be verified and re-
placed, if necessary. On the other hand, the manifold gasket must be replaced every 2 years and every time the
manifold is opened, regardless of the time elapsed. After replacing the external silicone gasket, it is mandatory
to check the fume tightness.
2
1
62
87