Immergas VICTRIX TERA V2 24 PLUS EU Instructions And Recommendations page 58

Hide thumbs Also See for VICTRIX TERA V2 24 PLUS EU:
Table of Contents

Advertisement

Error
Anomaly signalled
Code
Anomaly pump
60
blocked
Air in circulator
61
Return/flow probe
70
exchange
Return and/or flow
75
probe malfunction
Flow and/or return
probes temperature
76
drift
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Service Centre)
58
Cause
The pump is stopped due to one of the following causes:
Impeller blocked, electrical fault.
Air is detected inside the pump; the pump cannot work.
In case of an incorrect boiler wiring connection the error is
detected.
Possible failure of one or both system return and flow
probes.
A malfunction of one or both system return and flow
probes is detected.
Boiler status / Solution
Try to unblock the pump as described
in the relative section. If normal
conditions are restored the boiler
restarts without having to be reset (1).
Vent the pump and the central heating
circuit. If normal conditions are
restored the boiler restarts without
having to be reset (1).
The boiler does not start (1).
The boiler does not start (1)
The boiler does not start (1)