A
B
1
12
3
3
4
11
10
38
A
C
2
A
6
7
6
5
Ducting
Ø 60
Rigid
Ø 50
Flexible
Ø 80
Rigid
Ø 80
Flexible
27
The adapter kit includes (Fig. 28):
N°1 Door adaptor Ø 100 or Ø 125 (1)
N°1 Door gasket made of neoprene (2)
N°4 Screws 4.2 x 9 AF (3)
N°1 Hex headed screw M6 x 20 (4)
N°1 Flat nylon washer M6 (5)
N°2 Door hole closure metal-sheet plate plug (6)
N°1 Plug gasket made of neoprene (7)
N°1 Toothed washer M6 (8)
9
N°1 Nut M6 (9)
8
N°1 (kit Ø 80/125) Concentric gasket Ø 60/100 (10)
N°1 (kit Ø 80/125) Flanged adapter Ø 80/125 (11)
N°4 (kit Ø 80/125) Hex headed screws M4 x 16 slotted screwdriver (12)
N°1 (kit Ø 80/125) Bag of lubricating talc
Supplied separately (Fig. 28):
N°1 Ducting kit door (A)
28
ADAPTOR
SHAFT
(A) mm
(B) mm
66
106
66
106
86
126
103
143
SHAFT
(C) mm
126
126
146