Immergas VICTRIX TERA V2 24 PLUS EU Instructions And Recommendations page 76

Hide thumbs Also See for VICTRIX TERA V2 24 PLUS EU:
Table of Contents

Advertisement

Id
Parameter
Parameter
Hydraulic
A0
model
Maximum
A1
pump speed
Minimum
A2
pump speed
Circulating
A3
pump mode
Storage tank
A4
flow offset
Storage tank
A5
activation offset
D.H.W.
A6
thermostat
76
Description
Defines the type of hydraulics in the boiler (0 = instant; 1 =
storage tank).
Defines the maximum operating speed of the circulator (If
A1 = A2 circulator operating at set speed).
Defines the minimum operating speed of the circulator.
Sets the pump operating mode
- DELTA T = 0: proportional head (see par. 1.29).
- DELTA T = 5 - 25 K: ∆T constant (see Par. 1.29).
Establishes the temperature to be added to the DHW
set-point to calculate the flow set to heat the storage tank (if
paired with a storage tank unit)
Temperature value to be subtracted from the DHW set-point
to calculate the boiler ignition to heat the storage tank (when
paired with a storage tank unit)
Establishes the switch-off method in DHW mode.
0 Fixed: the switch-off temperature is fixed at the maximum
value regardless of the value set on the control panel.
1 Correlated: the boiler switches off according to the
temperature set.
Range
Default
0 ÷ 1
1
A2 - 9
9
1 - A1
6
0 ÷ 25
15
5 ÷ 50 °C
25
0 ÷ 15 °C
3
0 ÷ 1
0
Customised