Immergas VICTRIX TERA V2 24 PLUS EU Instructions And Recommendations page 74

Hide thumbs Also See for VICTRIX TERA V2 24 PLUS EU:
Table of Contents

Advertisement

Id
Parameter
Parameter
Max DHW
P0
output
P1
Min CH output
P2
Max CH output
P3
-
Pump function-
P4
ing
External probe
P5
correction
P6
-
P7
Remote control
P8
-
74
Description
Defines the maximum heat output percentage of the boiler
during the D.H.W. mode compared to the maximum heat
output available (when paired with a storage tank unit)
Defines the minimum output percentage of the boiler in cen-
tral heating mode
Defines the maximum heat output percentage of the boiler
during the central heating mode compared to the maximum
heat output available
Not available for this model
The pump can function in two ways.
0 intermittent: in winter "mode" the circulator is managed
by the room thermostat or by the remote control.
1 continuous: in "winter" mode the circulator is always
powered and is therefore always in operation.
If the reading of the external probe is not correct it is possible
to correct it in order to compensate any environmental
factors.
Not available for this model
Sets the dialogue protocol with remote device
0: IMG BUS. Select this mode when connecting an Immer-
gas remote control (e.g.: CAR v2) to terminals 44/41
1 : Not available on this model
2: Select this mode when a commercial remote control is
connected to terminals 44-41 (with this selection, the
control of the domestic hot water adjustments and max set
central heating flow remains available on the boiler panel)
Not available for this model
Range
Default
0 - 100 %
100 %
0 - P2
0 %
VICTRIX
TERA V2 24
PLUS EU
G20 = 83
G31 = 83
0 - 100 %
VICTRIX
TERA V2 35
PLUS EU
G20 = 86
G31 = 86
-
-
0 - 1
0
-9 ÷ 9 K
0
-
-
0 - 2
0
-
-
Customised
value

Advertisement

Table of Contents
loading

This manual is also suitable for:

Victrix tera v2 35 plus eu

Table of Contents