Recommended Fuse And Cable Sizes - ESAB ROGUE EM 140 Instruction Manual

Table of Contents

Advertisement

4   INSTALLATION
1. Rating plate with supply connection data.
4.5

Recommended fuse and cable sizes

WARNING!
An electrical shock or fire hazard is probable if the following electrical service guide
recommendations are not followed. These recommendations are for a dedicated branch circuit
sized for the rated output and duty cycle of the welding power source
Supply voltage
Input current at maximum output
Maximum recommended fuse* or circuit breaker rating
* Time delay fuse
Maximum recommended fuse of circuit breaker rating
Minimum recommended cord size
Maximum recommended extension cord length
Minimum recommended grounding conductor size
Supply from power generators
The power source can be supplied from different types of generators. However, some generators may
not provide sufficient power for the welding power source to operate correctly. Generators with
Automatic Voltage Regulation (AVR) or with an equivalent or better type of regulation, with rated power
6 kW, are recommended.
0447 955 001
- 15 -
120 V, 1~50/60 Hz
120 V AC
21 A
25 A
32.0 A
14 AWG (2.08 mm
)s
2
50 ft. (15 m)
14 AWG (2.08 mm
2
)