Edid Configuration - Kensence KX-HDMI88 User Manual

4k 8x8 hdmi2.0 matrix switcher
Table of Contents

Advertisement

6.3.6 EDID Configuration

The DIP switcher status should be set as 1111 to enable Software EDID management
mode: RS232 control or Web-based GUI control.
Command
EDIDH[x]B[y].
EDIDPCM[x].
EDIDG[x].
EDIDMInit.
EDIDM[X]B[Y].
EDID/[x]/[y].
EDIDUpgrade[x
].
GetInPortEDID
[X]
%9979.
4K 8x8 HDMI2.0 Matrix Switcher
Function
Input port [y] learns the EDID from
output port [x].
If the EDID data is available and the
audio part supports not only PCM
mode, then force-set it to support PCM
mode only. If the EDID data is not
available, then set it as initialized EDID
data.
Set the audio part of input port [x] to
PCM format in EDID database.
Get EDID data from output [x] and
display the output port number.
Restore the factory default EDID data
for each input.
Manually EDID switching. Enable input
[Y] to learn the EDID data of output [X].
If the EDID data is not available, then
set it as initialized EDID data.
Set the EDID data of input port [x] to
built-in EDID No. [y]. [y]=0~11,
correspond to the 12 embedded EDID
data separately
Upgrade EDID data via the RS232 port.
X represents the input port, and x=9
represents all input ports.
When the switcher receives the
command, it will show a message to
prompt you to send EDID file (.bin file).
Operations will be canceled after 10
seconds.
Get the EDID data of input [x], [x]=1~8
Get the DIP switcher status
14
Feedback Example
EDIDH[x]B[y]
EDIDPCM[x]
Hexadecimal EDID
data and carriage
return character
EDIDMInit.
EDIDM[X]B[Y]
EDID/[x]/[y]
Please send the EDID
file
EDID Upgrade OK!
EDID RS232 GUI
CONTROL 1111

Advertisement

Table of Contents
loading

Table of Contents