4. Hook the front ends of the Frame Covers (105,
106) together. Attach each Frame Cover to the
Frame (2) with three M4 x 16mm Self-tapping
Screws (79).
5. Have a second person hold the Upright (6) near
the Frame (2) as shown.
Pull the Wire Harness (48) and the Coaxial
Cable (109) out of the Frame (2) and insert them
upward through the Upright (6). Do not let the
Wire Harness, the Coaxial Cable, or the Pulse
Wire (110) fall into the Upright; use a piece of
tape or an elastic band to hold the wires in place
until step 13.
Insert the Upright (6) into the Frame (2). Attach
the Upright with three M8 x 16mm Button
Screws (95) and three Star Washers (100).
Avoid pinching the Wires (48, 110) and the
Coaxial Cable (109) between the Upright and
the Frame.
4
79
2
79
105
5
6
2
100
95
7
106
110
109
48
95
100
100
95
Avoid pinching
the wires and
cable during
this step