Download Print this page

Communications Error Code - Brother DCP-7057 Service Manual

Laser mfc
Hide thumbs Also See for DCP-7057:

Advertisement

3.3

Communications Error Code

Code 1 Code 2
10
08
11
01
11
02
11
03
11
05
11
06
11
07
11
10
17
07
20
01
20
02
20
03
20
04
20
05
20
06
20
07
20
08
20
09
20
0A
20
0B
20
0C
32
01
32
02
32
10
32
11
32
12
32
13
*1 Available in German models only.
Wrong number called.
No dial tone detected before start of dialing.
Busy tone detected before dialing.
2nd dial tone not detected.
No loop current detected.
Busy tone detected after dialing or called.
No response from the remote station in sending.
Unobtainable tone detected after dialing.
No response from the calling station in receiving.
Unable to detect a flag field.
Carrier was OFF for 200 ms or longer.
Abort detected ("1" in succession for 7 bits or more).
Overrun detected.
A frame for 3 seconds or more received.
CRC error in answerback.
Echo command received.
Invalid command received.
Command ignored once for document setting or for dumping-
out at turn-around transmission.
T5 time-out error
CRP received.
EOR and NULL received.
Remote terminal only with V.29 capability in 2,400 or 4,800 bps
transmission.
Remote terminal not ready for polling.
Remote terminal not equipped with password function or its
password switch OFF.
Remote terminal not equipped with or not ready for
confidential mailbox function.
Remote terminal not equipped with or not ready for relay
function.
No confidential mail in the remote terminal.
2-22
Cause
*1
Refer to:
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101
2-101