  • Page 1 Weather Station · MeteoTemp BF Instruction manual...
  • Page 2 Desidera ricevere informazioni esaustive su questo prodotto in una lingua specifica? Venga a visitare il nostro sito Web al seguente link (codice QR Code) per conoscere le versioni disponibili. www.bresser.de/P7007511 GARANTIE · WARRANTY · GARANTÍA · GARANZIA www.bresser.de/warranty_terms RECYCLAGE (TRIMAN/FRANCE)
  • Page 3: Table Of Contents

    Table of contents Imprint .....................  5 Validity note ....................  5 Features .................... 6 About this Instruction Manual .............  6 General safety instructions.............. 7 Parts overview and scope of delivery .......... 10 Screen display .................. 11 Before commissioning .................  12 Power supply .................. 13 10 Battery level indicator .................
  • Page 4 20 Weather trend.................. 20 21 Connecting remote sensors .............. 20 22 MAX/MIN weather data ................. 21 23 Backlight/Display dimming.............. 21 24 Disposal.................... 21 25 Technical data .................. 22 26 Warranty.................... 23 27 EC declaration of conformity .............. 23 28 UKCA declaration of conformity ............ 23...
  • Page 5: Imprint

    We ask for your understanding that unsolicited returns cannot be processed. Errors and technical changes excepted. © 2023 Bresser GmbH All rights reserved. The reproduction of this documentation - even in extracts - in any form (e.g. photocopy, print, etc.) as well as the use and distribution by means of electronic systems (e.g.
  • Page 6: Features

    3 Features • Weather forecast, temperature and humidity • Indoor comfort indicator and mould warning function • Alarm function for temperature and humidity • Heat index and dew point • Min./max. value memory • DCF time (12- or 24-hour display) and date •...
  • Page 7: General Safety Instructions

    5 General safety instructions DANGER Risk of an electric shock! This device contains electronic parts that are powered by a power source (AC adapter and/or batteries). Improper use of this product may result in electric shock. Electric shock can cause serious or fatal injuries. It is therefore imperative that you observe the following safety information.
  • Page 8 • Operate the device only in a completely dry environ- ment and do not touch the device with wet or damp body parts. DANGER Danger of suffocation! Improper use of this product may result in suffocation, es- pecially for children. It is therefore imperative that you ob- serve the following safety information.
  • Page 9 • Do not disassemble the device! In the event of a defect, please contact your dealer. They will contact the Service Center and can arrange the return of this device for re- pair if necessary. • Do not expose the device to high temperatures and protect it from water and high humidity.
  • Page 10: Parts Overview And Scope Of Delivery

    6 Parts overview and scope of delivery Illustration 1: All parts of the base station (top), the sensors (bottom right) and the AC power adapter (bottom left) in overview. Display frame Snooze/Light key Display area “Indoor” [UP] Touch key [DOWN] Touch key [ALERT] Touch key Display area “Forecast”...
  • Page 11: Screen Display

    Euro plug adapter UK plug adapter Adapter fixture Locking knob DC barrel connector Scope of delivery: 1 x base station (A), 1 x outdoor sensor (B), 1 x AC power ad- apter (C) with 2 x plug adapters (D) Also required (not included): 2 pcs.
  • Page 12: Before Commissioning

    D13 Info on highest (MAX) or lowest D14 Indoor temperature (°C or °F se- (MIN) value lectable) D15 Climate indicator D16 Indoor humidity (in %) D17 Battery level indicator D18 Touch control panels D19 Weather forecast (24 hours) D20 Outdoor humidity (in %) D21 Outdoor temperature (°C or °F se- D22 Selected sensor channel lectable)
  • Page 13: Power Supply

    changed. If, for example, only the batteries in the sensor are replaced, the signal may subsequently not be received at all or not be received correctly. Note that the actual range depends on the respective con- struction materials used for the buildings as well as the re- spective position of the base unit and the outdoor sensor.
  • Page 14: Battery Level Indicator

    To replace the plug adapter, hold down the locking but- ton and turn the plug adapter in the "OPEN" direction and remove it from the adapter holder. Then perform step 1 to mount another plug adapter. NOTE: Alternatively, operation using batteries (2 x AAA/ LR03) is also possible.
  • Page 15: Automatic Time Setting

    When replacing one set of batteries, always remove the batteries from the other part of the unit and reinsert them in the correct order (see chapter "Setting up power supply"). Replace the batteries to be changed in the corresponding part of the device with a completely new set with full capacity.
  • Page 16: Alarm Setting

    Finally, press the [SET] key to save the settings and exit setting mode. NOTICE! If no key has been pressed for 20 seconds, the set- ting mode is automatically exited. The changes made up to that point are saved. 13 Alarm setting Setting the alarm time In the normal display mode, press the [SET] key re- peatedly to switch to the alarm time display (AL).
  • Page 17: Snooze Function

    14 Snooze function When the alarm sounds, press the snooze/light key to activate the snooze function. The alarm sounds again after 5 minutes. When the alarm sounds, press any other key to stop the alarm until the set alarm time is reached again. If no key is pressed, the alarm is automatically switched off after 2 minutes.
  • Page 18: Receiving Measurements Automatically

    Press the [UP] or [DOWN] key to activate or deactivate the temperature alarm. The warning symbol is dis- played for the activated range. If one of the set limit values is reached, the symbol for the temperature alarm flashes and a warning tone (two beeps per second) sounds for about 5 seconds.
  • Page 19: Weekday Display

    18 Weekday display This weather station shows on the display the first three let- ters of the respective weekday in the selected language. Ex- ample: MON = Monday, TUE = Tuesday etc 19 Clima indicator This weather station displays indoor and outdoor climate comfort level info based on measured humidity.
  • Page 20: Weather Trend

    Temperature Humidity Display 79%<=H<=87% H>=88% T>=40.1°C (T>=104.1°F) 20 Weather trend Illustration 3: Graphical representation of the weather trend Sunny Partly sunny Cloudy Rainy Stormy Snow 21 Connecting remote sensors The Weather Station can display the readings from up to 3 wireless sensors* of the same type. Each radio sensor must be set to a separate channel.
  • Page 21: Max/Min Weather Data

    Press the [CH] key for approx. 2 seconds to initiate the search for a sensor. NOTICE! Each connected wireless sensor must be set to a different channel. If only one wireless sensor is connected, it should be set to channel 1. *one wireless sensor included, others optionally available 22 MAX/MIN weather data The maximum and minimum readings for indoor and out-...
  • Page 22: Technical Data

    According to the European Directive 2012/19/EU on Waste Electrical and Electronic Equipment and its transposition into national law, used electrical equipment must be collected sep- arately and recycled in an environmentally sound manner. Batteries and rechargeable batteries must not be disposed of with household waste.
  • Page 23: Warranty

    28 UKCA declaration of conformity A "Declaration of Conformity" in accordance with the applic- able directives and relevant standards has been issued by Bresser GmbH The full text of the UKCA Declaration of Con- formity is available at the following web address: www.bresser.de/download/7007511/ UKCA/7007511_UKCA.pdf...
  • Page 27 (de preferencia por e-mail). E-Mail: service@bresseruk.com E-Mail: servicio.iberia@bresser-iberia.es Telephone*: +44 1342 837 098 Teléfono*: +34 91 67972 69 BRESSER UK Ltd. BRESSER Iberia SLU Suite 3G, Eden House c/Valdemorillo,1 Nave B Enterprise Way P.I. Ventorro del Cano Edenbridge, Kent TN8 6HF 28925 Alcorcón Madrid...
  • Page 28 Bresser GmbH Gutenbergstraße 2 46414 Rhede · Germany www.bresser.de @BresserEurope...

This manual is also suitable for:

40079220797837007511

Table of Contents