General Technical Data - Keller CellaTemp PX1 Series Manual

Pyrometer
Hide thumbs Also See for CellaTemp PX1 Series:
Table of Contents

Advertisement

Operating instructions CellaTemp PX 1x 2x 3x

20 General technical data

Pyrometer
Analogue output
Switching output OUT1
Switching output OUT2
Ambient temperature
IO-Link revision
SIO mode
Transmission rate
Storage temperature
Permissible humidity
Power supply
Current consumption
Housing material
Weight
Connectivity
Protection
Configuration parameter
0(4) -20 mA linear according NAMUR 43,
switchable, scalable load 500 Ω
PNP Open Collector outputs 24 V, ≤ 150 mA
switch point [°C]/ return switch point [°C],
hysteresis ≥ 1 K, on/switch-off delay, NC/ NO or
IO-Link
PNP Open Collector outputs 24 V, ≤ 150 mA
switch point [°C]/ return switch point [°C], hy-
steresis ≥ 1 K, on/switch-off delay, NC/ NO
0- 65 °C (without cooling)
V1�1, download compatible to V1�01
yes, supported
COM2 (38�400 Baud)
-20 – 80 °C
95 % r�H� max� (non condensing)
24 V DC +10 % / -20 % ripple ≤ 200 mV
≤ 135 mA
≤ 150 mA with laser pilot light
≤ 175 mA with camera
Stainless steel
Approx� 1 kg (according model)
5-pin connection M12 (A coded)
IP 65 according DIN 40050
with screwed plug
Emissivity ε 10 - 110 %
Transmissions factor τ 10 - 100 %
Smoothing function t
Peak hold function 0�1 – 999�9 s ATD function
42
0�1 – 999�9 s
98

Advertisement