Error Codes

Error codes are listed below. Even in an error condition the unit keeps track of the amount dispensed. With any error
code displayed you can:
Select Manual option on Home Screen.
Error code is cleared. Unit switches to Manual mode and dispensed amount is displayed.
Select reset option.
Error code is cleared, Unit switches to Auto mode and the present amount is displayed.
Error Code
Err 1
Err 2
Err 4
Err 5
Err 6
Err7
312865A
Cause
Battery voltage is low
Switch Error: Error occurred with
pick-up in internal gear.
or
Unit was dropped or unit encountered
excessive vibration during shipping.
Flow has continued after it should
have shut off.
or
Flow has occurred in lockout condi-
tion.
In Manual Mode only.
The unit has dispensed the shut-off
default amount and has stopped fluid
flow.
A present dispense amount of zero
was entered for the dispense or is
stored as the default and a Preset
dispense was attempted.
Battery voltage is too low.
or
CAP ERROR: Error has occurred in
control.
Troubleshooting
Solution
Change battery, page 26.
Ensure that your flow rate is not
higher than 14 gpm (37.8 lpm). For
further assistance, contact your
Graco distributor.
Select Reset, item G, page 18.
Check for low battery symbol and
replace batteries if indicated, page
26. For further assistance, contact
your Graco distributor.
Navigate to Home screen. Then
re-enter Dispense Screen.
Select Reset, item G, page 18 and
dispense again.To change the
shut-off default amount, see
Units/Limits Screen, page 12.
Enter an amount that is not zero. See
Preset Dispense Screen, page 19.
Change battery, page 26.
Replace electronic bezel assembly.
Use Electronic Repair Kit. (See ME
Meter Parts page 26 or PE Meter
Parts page 30 to identify which kit is
required for your meter).