Remove the Wiring Cover:

To remove the wiring cover:
• Place a small slot screwdriver or similar tool into the slot
located on the top of the thermostat.
• While pushing against the plastic tab, pull the top of the
front cover so that it pivots around the bottom edge of
the thermostat's base.

Mounting the Thermostat

If a single gang switch box is used, an Adaptor Plate 007
is required to mount the thermostat to the box.
• Fasten the base of the thermostat to the adaptor plate.
• Feed the wiring through the openings in the back of the
adaptor plate and thermostat.
• Use the upper and lower screw holes to fasten the
adaptor plate to the box.
007 Adaptor
Plate
Thermostat
Base
Thermostat
Mounted on switch box

Wiring Symbols

Dry contact switch. Operates a device.
Powered switch. 24 V (ac), switched
output to valve, pump relay etc.
Factory jumper.

Electrical Drawings

The electrical drawing examples on the following
pages show the 542 in common applications. Choose
the drawing that most accurately depicts the components
in your system and use that drawing as a guide to aid in
wiring your system.
These are only concept drawings, not engineered drawings.
They are not intended to describe a complete system nor
any particular system. It is up to the system designer to
Stud
Switch
Box
3
1
/
"
4
(83 mm)
3 of 8
Remove cover
2
If a switch box was not used, mount the thermostat directly
to the wall.
• Feed the wiring through the openings in the back of the
thermostat.
• Use screws in the screw holes to fasten the thermostat
to the wall. At least one of the screws should enter a
wall stud or similar rigid material.
Thermostat
OR
Mounted on wallboard
Do not apply power to these terminals.
Serious control damage will result.
tekmarNet
determine the necessary components for and configuration
of the particular system being designed including additional
equipment isolation relays (for loads greater than the
controls specified output ratings) and any safety devices
which in the judgement of the designer are appropriate in
order to properly size, configure and design that system
and to ensure compliance with building and safety code
requirements.
Push tab
1
Stud
Thermostat
Base
Wall
2
2
3
3
/
/
"
"
8
8
(60 mm)
(60 mm)
screwhole
screwhole
®
4
© 2008
W 542 - 12/08