tekmarNet
®
4 Thermostat 540
1.
Location
Exterior
Wall
3.
Install Mounting Base
Adaptor
Plate 007
Thermostat
Base
5.
Switch Settings
Switch Position Action
SETBACK Allow thermostat to respond to
ON
available schedule. Requires Timer 033.
1
OFF
OFF No setback schedule response.
SCENE Allow thermostat to respond to
ON
scenes. Requires User Switch 479.
2
OFF
OFF No scene response.
NONE The thermostat is not part of a
ON
cooling group.
3
COOL MASTER 1 The thermostat is a
OFF
master of cooling group number 1.
LOCK Locked to 'User' access level. Set
ON
to Lock when installation completed.
4
UNLOCK Unlock to access all settings.
OFF
Set to Unlock during installation.
Quick Setup Guide
Interior
Wall
5 feet
1.5 m
Thermostat
Base
OR
Switch
Box
2.
Remove Mounting Base
4.
Wiring
Fan
G
Y
R
D
X
Cooling Equipment
Wall
tN4 Wiring Center
tN4 Zone Manager
6.
Close Thermostat
pivot
tab
1 of 2
Cooling
1 Stage
Cooling
1 Stage
Use at least 75°C conductors
Fan
For instructions see brochure
tN4
C
R
W
1
2
3
4
or
R
tN4
C
W
© 2010
Q 540
08/10
Zoning
Replaces: New
tNt 540
One Stage Heat /
One Stage Cool / One Fan
Power:
24 V ±10% 50/60 Hz 1.8 VA
56 VA fully loaded
Relays:
24 V (ac) 2 A
ON
Made in
Canada
1 2 3 4
1
2
3
4
Switch
Setting
Location
Q 540 - 08/10