- User Brochure
tekmarNet
®
4 Thermostat 543
Congratulations
on the purchase of
your tekmar programmable
thermostat with communication.
This thermostat combines
easy-to-use programming with
advanced features to increase
both comfort and energy
efficiency.
Your tekmar thermostat allows
you to:
• • Set a single schedule for your
heating system that all of your
tekmar thermostats can follow.
• • Adjust the time and date on all
your tekmar thermostats from a
single thermostat
• • View the outdoor temperature
on all of your tekmar thermostats.
• • Easily set up custom "Scenes"
to match your home and lifestyle.
• • Easily override your tekmar
thermostats if you are planning an
extended absence.

Table of Contents

Display .................................................................... 2
Symbols Description ............................................... 2
User Interface ......................................................... 3
Viewing Current Temperatures ............................... 4
Viewing the Room Set Temperature ....................... 4
Adjusting the Temporary Zone Hold ....................... 6
Choosing the Mode of Operation ............................ 6
Viewing the Current Time ....................................... 7
Setting the Time ..................................................... 7
Selecting a Scene ................................................... 8
Extended Absences ................................................ 9
Selecting a Schedule .............................................. 9
Units of Temperature .............................................11
Backlight ................................................................11
Cleaning the Thermostat ......................................11
Error Messages .....................................................11
Warranty ................................................................12
1 of 12
U 543
08/07
© 2007
U 543 - 08/07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 543 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tekmar 543

  • Page 1: Table Of Contents

    Error Messages .............11 • • View the outdoor temperature Warranty ..............12 on all of your tekmar thermostats. • • Easily set up custom “Scenes” to match your home and lifestyle. • • Easily override your tekmar thermostats if you are planning an extended absence.
  • Page 2: Display

    Indicates that the temperature has been Indicates this thermostat is a schedule temporarily adjusted from the scheduled master. event temperature. N4 COMMUNICATION SCHEDULED EVENT Indicates when a communication network Indicates the current scheduled event. is detected. © 2007 U 543 - 08/07 2 of 12...
  • Page 3: User Interface

    These menus are listed in the Menu Field on the top left hand side of the display. Use the Menu button to advance to the next menu. Continue to next Item Continue to next Item Continue to next Menu 3 of 12 © 2007 U 543 - 08/07...
  • Page 4: Viewing Current Temperatures

    To view the Room Set temperature: 1. Use the Menu button to select the View menu. 2. Use the Item button to select Room Set. © 2007 U 543 - 08/07 4 of 12...
  • Page 5: Adjusting The Room Set Temp (No Schedule)

    Current schedule Press Up or Down Press Up or Down status indicates a Button to adjust the Button to adjust the schedule is in use “Wake” temperature. “UnOcc” temperature 5 of 12 © 2007 U 543 - 08/07...
  • Page 6: Temporary Room Set Adjustment (Schedule)

    1. Use the Menu button to select the Adjust menu. 2. Use the Item button to select the Mode item. 3. Use the Up or Down button to select either Off or Heat. © 2007 U 543 - 08/07 6 of 12...
  • Page 7: Setting The Floor Warming Temperatures

    Step 4: Use the Item button to advance to the next item. The minutes begins to flash. Use the Up or Down button The day begins to flash. Use the Up or Down button to set to set the minutes. the day. 7 of 12 © 2007 U 543 - 08/07...
  • Page 8: Selecting A Scene

    Please refer to the Job Record J 543 for a record of how Refer to the Scene table below for a description of each your installer made these settings scene.
  • Page 9: Extended Absences

    Extended Absences If you are going away for an extended period of time, the If you have multiple tekmar thermostats installed, you need AWAYHOLD feature allows you to override the regular only to do the following on one thermostat. schedule of the thermostat for a set number of days.
  • Page 10 The installer of this thermostat may have already entered 4. Use the Item button to advance to the next available event. a schedule. Please refer to Job Record J 543. 5. Repeat steps 3 and 4 for all of the available events. To set the schedule: 1.
  • Page 11: Units Of Temperature

    Symbol appears and a description of the error message is displayed. To troubleshoot how to correct the error, please refer to the Data Brochure or contact a qualified installer. An electronic version of the Data Brochure D 543 is available on the tekmar website: www.tekmarcontrols.com. Warning Symbol 11 of 12 ©...
  • Page 12: Warranty

    Purchaser shall indem- such Product sale and acknowledges that it has read nify and hold tekmar harmless from and against any and all and understands same. claims, liabilities and damages of any kind or nature which...