Setting To Work - Connection To The Power Supply; Extensions - Nilfisk-Advance ALTO ATTIX 140 Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
ATTIX 140 - ATTIX 150
Setting to work - connection to the power
supply
Make sure that the vacuum cleaner is in perfect
condition before commencing work.
Before plugging the vacuum cleaner into the
electrical mains, make sure that the voltage rating
indicated on the data plate corresponds to that of
the electrical mains.
Plug the vacuum cleaner into a socket with a
correctly installed ground contact/connection.
Make sure that the vacuum cleaner is off.
The plugs and connectors of the connection
cables must be protected against splashed water.
Make sure that connections to the electrical
mains and plug are correct.
Use the vacuum cleaners only when the cables
that connect to the electrical mains are in perfect
condition (damaged cables could lead to electric
shocks!).
Regularly check that the electric cable does not
show signs of damage excessive wear, cracks or
ageing.
When the vacuum cleaner is operating:
Do not crush, pull, damage or tread on the cable
that connects to the electrical mains.
Only disconnect the cable from the electrical
mains by removing the plug (do not pull the
cable).
Only replace the electric power cable with one
of the same type as the original: HO7 RN - F. The
same rule applies if an extension is used.
The cable must be replaced by the manufacturer's
Service Centre staff or by equivalent qualified
personnel.
GB
C320
WARNING!
WARNING!

Extensions

If an extension is used, make sure it is fit for the power draw
and protection degree of the vacuum cleaner.
Minimum section of extension cables:
Maximum length = 20 m
Cable = HO7 RN - F.
Max power (kW)
Minimum section (mm
)
2
WARNING!
Sockets, plugs, connectors and installation of the
extension cable must maintain the IP protection
degree of the vacuum cleaner, as indicated on the
data plate.
WARNING!
The vacuum cleaner's power socket must be
protected by a differential circuit-breaker with surge
current limitation, that shuts off the power supply
when the current dispersed towards ground exceeds
30 mA for 30 ms or an equivalent protection circuit.
WARNING!
Never spray water on the vacuum cleaner: such action
constitutes a danger hazard for persons and could
short circuit the power supply. Consult the latest
edition of the European Union Directives, the Laws
in the country of use and the current standards in
force (UNI - CEI - EN), particularly European standard
EN60335-2-69.
4
3
5
15
22
2.5
4
10
16
11/2008

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alto attix 150