Note
It is not possible to remove the heat exchanger from the
ventilation unit. Cleaning the heat exchanger is not necessary
under normal conditions if the correct filters are used and
replaced on schedule.

6.2. Check for unusual noises

If the ventilation unit produces unusual noises or vibrations, this
may indicate that the motor module or bypass valve is faulty.
Consult Inspecting and cleaning the fan on page 30 and/or
Inspecting and cleaning the bypass valve to determine the cause
and resolve the problem.
30

6.3. Inspecting and cleaning the fan

ä
Caution!
If the unit is ceiling mounted, be careful to avoid being hit by
swinging wire brackets when removing the ventilation unit.
Follow the steps below when inspecting and cleaning the fan:
a) Disconnect power to the ventilation unit.
b) Unlock the duct adapters using a screwdriver.
2x
c) Tilt the ventilation unit away from the wall, ceiling or floor. Then
carefully remove the unit from the wire brackets and place it on
the floor.
d) Unscrew the screws attaching the motor module to the housing
and remove the screws.