BK8053-000107 Rev D
4.4.3 Settings > Marking Gas Type
Choose between Nitrogen (N2) Plasma Gas with Nitrogen (N2) Shield Gas, or
Argon (Ar) Plasma Gas with Air (Air) Shield Gas.
4.4.4 Settings > Torch Enable
If the System has been commissioned with more than one torch (multi-torch setup),
select the corresponding torch numbers to enable them in the FineLine UI. When
more than one torch is enabled, all setting are applied to all torches.
Torch 1 is enabled by default.
Enabled torch numbers are green. Red torch numbers have been commissioned but
are not enabled. Grey torch numbers have not been commissioned.
If more than one torch is enabled, press the Select Torch Button to choose the
Active Torch (Torch 1 = T1, Torch 2 = T2, etc.).
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
For multi-torch setups, press the
Select Torch Button
to choose the Active Torch.