Lincoln Electric FineLine 300HD Operator's Manual page 69

Plasma system
Table of Contents

Advertisement

BK8053-000107 Rev D
Status Screen
Press the Status button ( ) to expand the Status Screen shown below. Colored
LEDs indicate status of the corresponding item; green means good or active, red
means error, and not illuminated means not active. Press the Status Bar or Status
button (
) to collapse the Status Screen and return to the previous screen.
Group
Application – each
LED illuminates
green as described.
Output Power
Coolant – Green
LED illuminates when
coolant system is on
and there are no
coolant errors.
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Item
CutLinc: All devices are powered and connected to
the server.
Gas Controller: Gas Controller outputs are enabled.
Power Supply: Power Supply outputs are enabled.
Ready to Purge: System is on; awaiting gas purge / purge
completed.
Ready to Cut: System is on, gas purge completed and
no System faults. All necessary System
requirements have been met and the
System is ready to cut.
Current: Actual Power Supply output current.
Voltage: Actual Power Supply output voltage.
Temperature: Actual coolant temperature. Coolant LED
illuminates Red when temperature is too
high.
Flow: Actual coolant flow. Coolant LED
illuminates Red when flow is too low.
Page 69 of 132
FineLine 300HD Plasma System
Refer to the descriptions below.
Refer to Sections 4.3.6, 4.4.6,
and 4.4.7.
Description

Advertisement

Table of Contents
loading