Lincoln Electric FineLine 300HD Operator's Manual page 106

Plasma system
Table of Contents

Advertisement

FineLine 300HD Plasma System
Source FLGC
Event
Hex
Code
2560
0xA00
2561
0xA01
2562
0xA02
2563
0xA03
3083
0xC0B
3844
0xF04
4099
0x1003
4100
0x1004
4101
0x1005
4102
0x1006
4103
0x1007
4104
0x1008
4105
0x1009
4108
0x100C
4110
0x100E
4111
0x100F
4113
0x1011
4114
0x1012
4115
0x1013
4116
0x1014
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Description
MA INSUFFICIENT POINTS
MA POLYNOMIAL ORDER TOO
LARGE
MA SINGULAR MATRICES
INVALID
MA FPC COEFFICIENT ERROR
CAN TX BUSY ERROR
GC CANNOT CREATE GAS
OBJECT
EX INVALID WAYPOINTS
EX INVALID PLASMA GAS
PRESSURE
EX INVALID SHIELD GAS
PRESSURE
EX INVALID PREFLOW GAS
PRESSURE
EX INVALID POSTFLOW GAS
PRESSURE
EX UNDEF PREFLOW PRESSURE
EX UNDEF SHIELD PRESSURE
EX LOST Y VALUE
EX REMOTE POWER OFF
EX PURGING
EX PURGING PLASMA
PRESSURE TOO LOW
EX PURGING SHIELD PRESSURE
TOO LOW
EX PURGING MARKING
PRESSURE TOO LOW
EX PURGE GASES BEFORE
FIRST CUT
Page 106 of 132
BK8053-000107 Rev D
Possible Resolution
Report issue to Lincoln
Electric service department.
Report issue to Lincoln
Electric service department.
Report issue to Lincoln
Electric service department.
Report issue to Lincoln
Electric service department.
Compare pressure displayed
on Parameters screen to cut
chart values in manual
Compare pressure displayed
on Parameters screen to cut
chart values in manual
Compare pressure displayed
on Parameters screen to cut
chart values in manual
Compare pressure displayed
on Parameters screen to cut
chart values in manual
Power Supply has been turned
off via Off Button on HMI,
Power Button on Power
Supply, EStop has been
asserted or Power Supply
Fault.
Wait for purge to finish.
Output pressure at Gas
Controller is lower than 80psi
during purge. Check for
restrictions or leaks in supply
lines to Gas Controller. Check
for gas leak at output
connections, torch leads or at
torch connections.
Initiate a manual gas purge.

Advertisement

Table of Contents
loading