Download Print this page

Maximum Current - JLG SMART SYSTEM 1532E Instruction Manual

Analyzer kit

Advertisement

SECTION 1 - JLG SMART SYSTEM ™ ANALYZER KIT INSTRUCTIONS (1600258 CONTROLLER).
Table 1-3. Machine Model Default Settings Chart - (Machines equipped with 1600258 controller)
Adjustment
DRIVE ACCELERATION
DRIVE DECELERATION
LIFT ACCELERATION
LIFT DECELERATION
DECK EXT./RET. ACCELERATION
DECK EXT./RET. DECELERATION
DRIVE CREEP SPEED
LIFT CREEP SPEED
DECK CREEP SPEED
STEERING CREEP SPEED
STEER. DR. SPEED COMP.
DRIVE FWD & REV SPEED MAX. (EATON
DRIVE MOTORS)
(WHITE DRIVE MOTORS)
LIFT UP SPEED MAXIMUM
LIFT DOWN SPEED MAXIMUM*
DECK RETRACTION SPEED MAX.
DECK EXTENSION SPEED MAX.
ELEVATION DRIVE CUT BACK**
POSITRAC HOLDING TIME**
GROUND LIFT UP SPEED
GROUND LIFT DOWN SPEED*
GROUND DECK IN SPEED
GROUND DECK OUT SPEED
HIGH DRIVE OVERCURRENT**
HIGH DRIVE TIME OUT**

MAXIMUM CURRENT**

IDLE TIME OUT
1-6
1532E
1932E
1.0
1.0
0.5
0.5
1.0
1.0
0.5
0.5
1.0
1.0
0.5
0.5
8
8
10
10
10
10
20
20
20
20
80
80
100
100
90
80-90
*
60-70*
70-80
60
60
100
100
25
25**
**
10**
10**
75
75
60-70*
60-70*
50
50
50
50
165**
165
**
5.0**
5.0**
220**
220**
10
10
– JLG Sizzor –
2033E
2046E
1.0
1.0
0.5
0.5
1.0
1.0
0.5
0.5
1.0
1.0
0.5
0.5
9
9
15
15
10
10
20
25
20
20
100
N/A
100
100
100
100
80-90*
90-100*
60
60
100
100
30
30
**
**
10**
10**
75
80
60-70*
60-70*
50
50
50
50
185
185
**
**
5.0**
5.0**
220**
220**
10
10
2646E
2658E
1.0
1.0
0.5
0.5
1.0
1.0
0.5
0.5
1.0
1.0
0.5
0.5
10
10
15
15
10
10
25
30
20
20
N/A
N/A
100
100
100
100
90-100*
90-100*
60
60
100
100
30
30
**
**
10**
10**
80
90-100
60-70*
60-70*
50
50
40
40
185
185
**
**
5.0**
5.0**
220**
220**
10
10
3120442

Advertisement

loading