5.2 Example of ConfigureCmd

FPort:0x07
Bytes
1
CmdID
CmdID– 1 byte
DeviceType– 1 byte – Device Type of Device
NetvoxPayLoadData– var bytes (Max=9bytes)
Description
Device
Config
ReportReq
Config
ReportRsp
R718N3xxx(E)
Series
ReadConfig
ReportReq
ReadConfig
ReportRsp
(1) Configure device parameters MinTime = 1min, MaxTime = 1min, CurrentChange = 100mA
Downlink: 014A003C003C0064000000
The device returns:
814A000000000000000000 (Configuration successful)
814A010000000000000000 (Configuration failed)
(2) Read device configuration parameters
Downlink: 024A000000000000000000
The device returns:
824A003C003C0064000000 (Current device configuration parameters)
1
DeviceType
Device
CmdID
Type
MinTime
0x01
(2bytes Unit:s)
0x81
0x4A
0x02
MinTime
0x82
(2bytes Unit:s)
Var(Fix =9 Bytes)
NetvoxPayLoadData
NetvoxPayLoadData
MaxTime
(2bytes Unit:s)
Status
(0x00_success)
Reserved
(9Bytes,Fixed 0x00)
MaxTime
(2bytes Unit:s)
9
CurrentChange
Reserved
(2byte Unit:1mA)
(3Bytes,Fixed 0x00)
Reserved
(8Bytes,Fixed 0x00)
CurrentChange
Reserved
(2byte Unit:1mA)
(3Bytes,Fixed 0x00)