Example Of Configurecmd - netvox R718KA User Manual

Wireless ma current meter interface, 4~20 ma
Hide thumbs Also See for R718KA:
Table of Contents

Advertisement

Device
Device
Type
R718KA
0x22
Uplink: 01220123074E0000000000
Byte
Value
1st
01
2nd
22
3rd
01
4th
23
5th
07
6th
4E
7th~11th
0000000000

5.2 Example of ConfigureCmd

FPort:0x07
Bytes
1
CmdID
CmdID– 1 byte
DeviceType– 1 byte – Device Type of Device
NetvoxPayLoadData– var bytes (Max=9bytes)
Description
Device
Config
ReportReq
R718KA
Config
ReportRsp
Report
Type
Battery (1Byte)
0x01
unit:0.1V
Attribute
Result
Version
DeviceType
ReportType
Battery
Current
7mA
FineCurrent
7.8mA
Reserved
1
DeviceType
Cmd
Device
ID
Type
MinTime
0x01
(2bytes Unit:s)
0x22
0x81
NetvoxPayLoadData
Current (1Byte)
unit:1mA
1
22
1
3.5v
23(HEX)=35(DEC),35*0.1v=3.5v
07(HEX)=7(DEC),7*1mA=7mA
4E(HEX)=78(DEC),78*0.1mA=7.8mA
0
NetvoxPayLoadData
MaxTime
(2bytes Unit:s)
Status
(0x00_success)
6
FineCurrent (1Byte)
unit:0.1mA
Resolution
-
-
-
-
Var (Fix =9 Bytes)
NetvoxPayLoadData
BatteryChange
CurrentChange
(1byte Unit:0.1v)
(1byte Unit:1mA)
(8Bytes,Fixed 0x00)
Reserved (5Bytes)
fixed 0x00
Reserved
(3Bytes,Fixed
0x00)
Reserved