23. Run a Test Panel in MAX by expanding NI-cDAQ<model number>-<serial number>»
Devices and Interfaces»NI cDAQ-<model number>, right-clicking your C Series
module, and selecting Test Panels to open a test panel for the selected module.
If the test panel displays an error message, refer to
New users can view and use the Voltage - Continuous Input VI, available in the
LabVIEW Example Finder. Experienced users can use the LabVIEW Sample Projects,
LabVIEW Real-Time Control (NI-DAQmx) and LabVIEW Waveform Acquisition and Logging
(NI-DAQmx).
For information about configuring network settings, refer to the Configuring
Note
Network Settings book of the MAX Remote Systems Help. In MAX, click Help»Help
Topics»Remote Systems. On the Contents tab, browse to LabVIEW Real-Time
Target Configuration»Configuring Network Settings.
For information about configuring the controller to launch an embedded stand-alone application
at startup, refer to the LabVIEW Help. For more information about setting up the controller as
an RT target, refer to the LabVIEW Help. For more information about configuring the controller
in MAX, refer to the MAX Help.
You can also change the network settings using Measurement & Automation Explorer (MAX)
on a host computer.
Troubleshooting Network Communication in
NI cDAQ-9138/9139 for LabVIEW Real-Time Chassis
If the controller cannot communicate with the network, you can use the IP RESET DIP switch
to manually restore the controller to the default network settings. When you reboot the controller
with the IP RESET DIP switch in the ON position, the controller attempts to connect to the
network using DHCP. If the controller is unable to obtain an IP address, it connects to the
network with a link-local IP address with the form
Complete the following steps to restore the controller to the default network settings.
1.
Move the IP RESET DIP switch to the ON position.
2.
Push the RESET button to cycle power to the cDAQ chassis.
1-12 | ni.com
Figure 1-5. IP RESET DIP Switch in ON Position
ON
ni.com/support
169.254.x.x
IP RESET
OFF
.
.