State
ON
Restore the cRIO-9022 to the default network settings. Reboot the cRIO-9022 to reset
the IP address and other TCP/IP settings of the cRIO-9022 to the factory defaults.
OFF
Keep this switch in the OFF position during normal operation.

NO APP Switch

The following table describes the ON and OFF states of the NO APP switch.
State
ON
Prevents a LabVIEW startup application from running when the cRIO-9022 powers
on.
OFF
Runs an application when the cRIO-9022 powers on. If you already have an
application configured to run when the cRIO-9022 powers on and you push the NO
APP switch from ON to OFF, the startup application is automatically enabled.
If you want to permanently disable the application from running when the
Note
controller powers on, you must disable it in LabVIEW. For more information about
automatically launching VIs when the controller powers on and disabling VIs from
launching when the controller powers on, refer to the LabVIEW Help.

USER1 Switch

You can define the USER1 switch to meet the needs of your application. The following table
lists the USER1 and FPGA LED descriptions. Use the RT Read Switch VI in your LabVIEW
RT embedded VI to define the purpose of this switch in your embedded application. For more
information about the RT Read Switch VI, refer to the LabVIEW Help.

RESET Button

Press the RESET button to reset the processor in the same manner as cycling power.
LEDs
The cRIO-9022 provides the following LEDs.
Table 3. IP RESET Switch States
Description
Table 4. NO APP Switch States
Description
NI cRIO-9022 User Manual and Specifications | © National Instruments | 11