Fixture Installation
Orbital Shower Cabinet R3 (OS8733-E)
5-06-0024
Publication date 2023-09-22

Advertisement

Table of Contents
loading

Summary of Contents for Orbital Systems R3 OS8733-E

  • Page 1 Fixture Installation Orbital Shower Cabinet R3 (OS8733-E) 5-06-0024 Publication date 2023-09-22...
  • Page 2 All rights reserved. No part of this document may be reproduced or copied in any form or by any means without written permission from Orbital Systems. The English language version of this document contains the original instructions. All other language versions are translations of the original instructions.
  • Page 3: Table Of Contents

    Installation Scenario Displayed in Manual ..............22 Prepare Shower Area ....................23 Install Drain ........................27 Install Wall Brackets ...................... 31 Prepare Orbital Systems Shower Head ..............34 Install Core Cabinet ...................... 35 Pipes & Connections ....................37 Install Audio ........................43 Install Drainage Pipe .....................
  • Page 4: Thank You For Your Purchase

    Read the Safety Guide before starting the installation or before operating the shower. Thank you for purchasing the Orbital Shower from Orbital Systems. To enjoy the full potential of the shower please read and follow the procedures in this manual. Make sure that you fully understand how to operate this shower and make sure that it is properly maintained in accordance with the instructions given in this manual.
  • Page 5: Approved Waterproofing Membrane

    Approved Waterproofing Membrane For installations outside of Sweden The following chapter describes a general waterproofing membrane procedure for instal- ling Orbital Shower in a wet-room area. Industry rules for how to apply waterproofing membrane in wet-room areas shall be applied. For installations in Sweden Following waterproofing membranes are approved according to Swedish regula- tions.
  • Page 6: Warranty

    For Warranty and Liability for Defects information, please visit Orbital Systems web https://orbital-systems.se/terms-conditions. Service Orbital Systems and our team of expert staff are available to assist you if you require product advice, experience any problems, need to purchase spare parts or to set up a service appointment.
  • Page 7: System Overview

    System Overview Orbital Shower Cabinet R3 (OS8733-E) Shower Head (optional) 2. Control Dial 3. Hand Shower Kit (Hand shower, Diverter and Holder) (optional) 4. Shower Unit (RSK 835 91 20) and Cabinet (RSK 205 50 28), located outside the shower area, or in an adjacent room 5.
  • Page 8: Installation System Requirements

    Installation System Requirements Connectivity Internet connection: Password protected Wi-Fi 2,4 GHz / 5 GHz or Ethernet. The installation kit contains components for either Wi-Fi connection OR Ethernet depending on what has been specified in the shower order. Electrical Supply Residual circuit breaker: One breaker per Shower Core Power supply: One Phase, 230VAC / 50 Hz / 16A...
  • Page 9: Installation Overview

    Installation Overview Orbital Shower Installation Options max. 3000mm The distance between the center of the Orbital Shower Core and the center of the Drain Unit must not exceed 3000 mm. Orbital Shower Core placed on the Orbital Shower Core placed on a same wall as the Drain Unit and wall perpendicular to the Drain Unit Shower Head.
  • Page 10 Orbital Shower Core placed in a Orbital Shower Core placed in a separate and heated room. separate and heated room. When installing the Orbital Shower Cabinet model, the Orbital Shower Core is installed as surface mounted wall mounting outside the shower area "in bathroom with water- proofing in the floor", or in an adjacent room "without waterproofing in the floor".
  • Page 11: Orbital Shower Installation Requirements

    Orbital Shower Installation Requirements W 500mm, H 915mm, D 150mm min. 160 mm E. max. 15 mm Finished floor height where it is level. The following constraints apply to the configuration of system components: A. The top of the Orbital Shower Core must be placed lower than the bottom of the head shower.
  • Page 12: Wall Installation

    Wall Installation The weight of the Orbital Shower Core is approx. 25 kg. The surrounding structure must be able to support the forces that will stress the attachment points. Use the holes located on the back and the sides to fixate the Core wall enclosure. IMPORTANT The cabinet must not be placed in a place for bathing or showering.
  • Page 13: Seal Mountings In Wet Zone

    Seal mountings in wet zone CAUTION For installation in Sweden according to current Industry Rules Safe Water Installation. All mountings in the wet zone must be sealed against the water- proofing layer of the wall or floor. Material for sealing must adhere to the substrate and be water-resistant, mold-resistant and aging-resistant.
  • Page 14: Shower Installation Overview

    Shower Installation Overview Available shower variants: A: Orbital Systems Shower Head & Hand Shower B: Orbital Systems Shower Head IMPORTANT The image is a principle sketch, and should not be used as an installation scenario. Cabinet must also be equipped with a leakage indicator.
  • Page 15: Recycling Optimisation Site Suggestion

    Recycling Optimisation Site Suggestion Recommended installation A fully enclosed shower area with floor heating is recommended to optimize recircula- tion rates. Page 15 of 59...
  • Page 16: Fixture Installation

    Fixture Installation Component Overview Fixture kit Floor fixtures Drain waterproofing membrane, 1x 2. Tiling frame set, 1x 3. Drain unit, 1x (RSK 711 54 63) 4. Outlet unit, 1x (RSK 711 99 33) 5. Cleaning wipe, 1x 6. Screws & Plugs kit, 1x Page 16 of 59...
  • Page 17 Fixture kit Wall fixtures Retainer Conduit (RSK 188 21 50),10x (Head & Hand)// 5x (Head) 2. Conduit Elbow (RSK 187 79 99 / 188 27 00), 5x (Head & Hand)// 3x (Head) 3. Screws, 6x 4. Fixture, 1x 5. Piping, PEX Hose with Conduit (RSK 188 23 36), 550 cm (Head & Hand)/ 350 cm (Head) 6.
  • Page 18 Audio kit Audio fixture 2. Speaker with speaker cable 3. Amplifier with amplifier cable and stub antenna 4. Puck antenna (only used for Orbital Shower Cabinet) 5. Rod antenna (only used for Orbital Shower Hatch) 6. Assembly kit to the rod antenna 7.
  • Page 19: Kit Measurements

    Kit Measurements 500 mm Head shower/Hand Control Dial shower Incoming hot water Ethernet Incoming cold water Drain Power supply Leakage indication Page 19 of 59...
  • Page 20: Recommended Kit Measurements

    Recommended Kit Measurements 150 mm 150 mm Finished floor height where it is level. Page 20 of 59...
  • Page 21 500 mm IMPORTANT Incoming tap water can only be drawn in from the back or top. IMPORTANT Leakage indicators must be mounted at least 60 mm from the floor or wall. Page 21 of 59...
  • Page 22: Installation Scenario Displayed In Manual

    Installation Scenario Displayed in Manual When installing the Orbital Shower Cabinet model, the Orbital Shower Core is installed as surface mounted wall mounting outside the shower area "in bathroom with water- proofing in the floor", or in an adjacent room "without waterproofing in the floor". The kit only allows for mounting on a wall..
  • Page 23: Prepare Shower Area

    Prepare Shower Area Mark the finished floor height where it is level (>170 mm). This mark will be used as measurement "X" in the installation process to ensure that there is enough space for the Drain Unit. >170 mm 20 mm 150 mm 95 mm min.
  • Page 24 CAUTION It is crucial that all noggin pieces are in level and set according to recom- mended measurements to avoid misalignment in the shower installation. 95 mm 95 mm 45 mm 4. Apply wall covering according to industry rules. 33,5 mm Ø75 mm Finished floor height where it is level.
  • Page 25 NOTICE Adjust slot in studs and wall covering depending on Hand Shower and Control Dial placement. Make sure to place the slots to the back, to avoid the wall covering screws damaging the pipes and hoses. Only valid for Orbital Audio installation Page 25 of 59...
  • Page 26 RSK 187 79 99 RSK 187 06 65 Draw Pipes, Pex Hoses with Conduits and Drain Conduits for Control Dial, Diverter and Drain Unit to the Orbital Shower Core mounting area. Use Conduit Elbows in kit to achieve the bends. See section Orbital Shower Installation Requirements [11] in Chapter...
  • Page 27: Install Drain

    Install Drain Drain unit and Outlet unit RSK 711 54 63 RSK 711 99 33 CAUTION Plumbing and electrical installation should be performed according to in- dustry rules. CAUTION Do not remove the Protective Cover until the Frame is being installed in a later step.
  • Page 28 Finished floor height where it is level. Drain Unit is centered in the shower area. Connect Drain Unit to the sewerage system as defined by industry rules. Page 28 of 59...
  • Page 29 Drain piping RSK 291 03 56 RSK 283 20 03 RSK 291 03 41 RSK 283 20 31 CAUTION Perform the installation in accordance with current Industry Rules Safe Water Installation: • A waste water pipeline shall be laid with falls along the entire length of the pipeline.
  • Page 30 Anchor the Pipes and Fittings according to industry rules. For installation in Sweden according to Safe Water § 4.4.1, pipes that are to be cast in, fastening devices are placed according to the supplier's installation instructions, alternatively at all branch pipes, sockets, bends, deposits and on straight sections to a sufficient extent to prevent the pipe's position from changing.
  • Page 31: Install Wall Brackets

    Install Wall Brackets NOTICE Following steps only valid for Orbital Systems Shower Head and Hand Shower. RSK 187 79 99 RSK 188 23 36 >100mm Page 31 of 59...
  • Page 32 Make sure the Shower Head and the Control Dial are centered vertically. CAUTION • The Orbital Shower Core shall be connected to the top inlet. • The Shower Head shall be connected to the bottom inlet. 150 mm Countersunk stainless steel screw Page 32 of 59...
  • Page 33 150 mm Countersunk stainless steel screw RSK 188 21 50 Anchor the Control Dial and Diverter Piping according to industry rules. Page 33 of 59...
  • Page 34: Prepare Orbital Systems Shower Head

    Prepare Orbital Systems Shower Head RSK 188 26 57/188 21 81 Measure and mark placement of Wallbox UNI Push. 1900mm - 2300mm Follow instructions provided for the Wallbox UNI Push. Mount the Wallbox with four screws from the front. Installation should be performed according to industry rules.
  • Page 35: Install Core Cabinet

    Install Core Cabinet The weight of the Shower Core is approx. 25 kg. The wall construction must be able to support this load. 500mm NOTE Two variants of screws are included in the kit from LK, short and long depending on the wall. Pan head stainless steel screw Page 35 of 59...
  • Page 36 Use the LKS plugs supplied with the Core cabinet to hide the screw heads. LKS Plug Page 36 of 59...
  • Page 37: Pipes & Connections

    Pipes & Connections Punch out one hole in the sheet metal on the back of the Core Cabinet. Page 37 of 59...
  • Page 38 Only valid for Orbital Audio Punch out holes in the perforated plate for the exciter cable. Ø 50mm Ø 40mm Ø 34mm Ø 32mm Page 38 of 59...
  • Page 39 min. 10mm max. 20mm Ø 32 mm Ø 25 mm Ø 16-20 mm Ø 12 mm Page 39 of 59...
  • Page 40 Prepare incoming water and electricity. Draw Cables and Hoses and use Pipe Clamps for anchoring. Use Pipe Clamps in kit to anchor piping for Shower Head and Hand Shower. CAUTION • The Orbital Shower Core shall be connected to the upper inlet of the Diverter Bracket.
  • Page 41 100 mm Page 41 of 59...
  • Page 42 Page 42 of 59...
  • Page 43: Install Audio

    Install Audio Following steps are only valid for Orbital Audio Check that the exciter is intact and attached to the back of Audio fixture before starting the installation. Install two studs in between the head shower and the control display, where Audio fixture will be placed.
  • Page 44 Draw the speaker cable from the back of Audio fixture to the wallbox. CAUTION Use the supplied rubber plug. Page 44 of 59...
  • Page 45 Strip the speaker cable and attach it to the amplifier. Connect the extension cable to the puck antenna. Page 45 of 59...
  • Page 46 Punch out one hole in the sheet metal. Remove the stub antenna from the amplifier, and replace it with the puck antenna. Mount the amplifier in the wallbox by loosening the nut from the lower bracket and threading the amplifier into the upper bracket. Attach the lower nut and tighten. Page 46 of 59...
  • Page 47: Install Drainage Pipe

    Install Drainage Pipe RSK 188 26 11 CAUTION • The Drainage Pipe must end in a wet zone area including moisture barrier and a floor drain, but cannot end inside the shower space. The inside diam- eter of the leakage indicator must be at least 20 mm. The outlet must not be placed closer than 60 mm from the waterproofing layer of the floor or adjacent wall.
  • Page 48: Prepare For Tiling

    Prepare for Tiling Raise the floor until it is level with the flange on the drain unit. Form a steep inclination according to industry rules (min. 2% inclination) towards the Drain Unit. Make sure that the lowest part of the inclination is in level towards the Drain unit surface.
  • Page 49 Apply wall covering according to industry rules. Only valid for Orbital Audio installation CAUTION Make sure to apply construction glue to all wallboard layers. Page 49 of 59...
  • Page 50: Apply Waterproofing Membrane

    Apply Waterproofing Membrane Waterproofing membrane shall be applied around 5 penetrations on the floor and wall. Provided by Customer: Waterproofing Conduit Membrane for Diverter 2. Waterproofing Conduit Membrane for Shower Head 3. Waterproofing Conduit Membrane for Control Dial 4. Waterproofing Conduit Membrane for Pipe to Orbital Shower Core Page 50 of 59...
  • Page 51 Roughen the metal surface of the Drain Unit and clean it with rubbing alcohol or similar. NOTICE To achieve optimal bonding, all surfaces should be clean and free of adhe- sion reducing substances (e.g. dust, acid, grease). Apply waterproofing glue to the Drain Unit's metal flange. Page 51 of 59...
  • Page 52 Spread the waterproofing glue with a fine-toothed glue spreader or brush. 4. Apply liquid membrane to the floor- and wall surface which the Drain Waterproofing Membrane is going to cover. Page 52 of 59...
  • Page 53 Apply the Drain Waterproofing Membrane around the Drain Unit. When mounting the Drain Waterproofing Membrane, make sure to cover both the floor and the wall. Firmly apply pressure and remove air pockets using a smoothing tool. Make sure no blisters or creases occur. Carefully mount Waterproofing Membrane and overlap by at least 50 mm.
  • Page 54 Apply Waterproofing Conduit Membrane according to chosen manufacturer to seal the conduits coming out of the wall. Make sure remaining surfaces are being waterproofed according to chosen water- proofing membrane manufacturer and industry rules. Page 54 of 59...
  • Page 55: Install Tiling Frame Set

    Install Tiling Frame Set Page 55 of 59...
  • Page 56: Tiling

    Tiling NOTE It is important to keep exactly 90 degree angles and set everything vertically / horizontally. It is also important that you do not smear fix over onto the black lacquered area on the Cabinet. Finally, it is recommended to place a thin sili- cone joint in the meeting with the tile strip and the Cabinet, mainly along the bottom side of the Cabinet hole, avoiding water flowing on to the fix.
  • Page 57 2 mm 2 mm Page 57 of 59...
  • Page 58: Final Preparations

    Final Preparations CAUTION The Orbital Shower will not function without executing above mentioned steps. Fixture Installation completed. Next step is to install the Orbital Shower Core, Control Dial, Shower Head and Hand Shower (including Diverter and Hand Shower Holder). See Technology Installation Man- ual for details.