Download Print this page

Orbital Systems Oas Installation Manual

Indo shower unit
Hide thumbs Also See for Oas:

Advertisement

Quick Links

Oas Indo Shower Unit Installation

Advertisement

loading

Summary of Contents for Orbital Systems Oas

  • Page 1 Oas Indo Shower Unit Installation...
  • Page 2 This manual applies to model OS8732 Ei2. (56)
  • Page 3 Thank you for purchasing the Oas shower system. To enjoy the full potential of the shower please read and follow the procedures in this manual. Make sure that you fully understand how to operate this shower and (56) make sure that it is properly maintained in accordance with the instructions given in this manual.
  • Page 4 Do not operate the shower system if water leaks from WARNING the appliance. The Oas shower system can be used by children aged 8 years and above and persons with Do not operate the shower system if it is frozen or reduced physical, sensory or mental capabilities suspected of being frozen.
  • Page 5 S A F E T Y I N S T R U C T I O N S The Oas recirculating shower system is designed for regular showering only. Do not use the shower to clean extreme soiling or pour corrosive chemicals or cleaners down the shower drain. Any other use of the system could seriously deteriorate the quality of the filtration system or damage the shower system.
  • Page 6 This is an earthed appliance, the connection to the best practice for the installation. All installations earth circuit is mandatory. should be completed by Orbital Systems or a certified partner or client. To ensure your The appliance shall be supplied through a installation goes smoothly read this manual class A GFCI (ground fault circuit interrupter).
  • Page 7 • Defects caused by faulty maintenance, incorrect installation or a faulty repair. Repairs should be carried out only by Orbital Systems, one of our certified service partners or the client only when certified. For showers outside of the warranty period spare parts are available for...
  • Page 8 S E R V I C E Orbital Systems and our team of expert staff including our certified Service Partners are available to assist you should you require product advice, experience any problems, need to purchase spare parts or to set up a service visit.
  • Page 9 TA B L E O F C O N T E N T S Installing the Shower Unit Installing the Shower Head (56) WiFi Setup & Track your Savings Installing the Hand Shower...
  • Page 10 I N S TA L L I N G T H E S H O W E R U N I T (56) watch video: https://bit.ly/2QNFVLP...
  • Page 11 C O M P O N E N T O V E R V I E W Hose Connection Indo Core Indo Panel Panel Lock + Magnetic Key Funnel Smart Sensor Unit Sensor Tank Sensor Cable Recirculation Hose Flush Hose Smart Sensor Lock (56) + half thread M4 (3 Hex), x1...
  • Page 12 (56) M3 (5.5mm driver) Remove Panel Template.
  • Page 13 (56)
  • Page 14 (56)
  • Page 15 Apply lubricant (56)
  • Page 16 If Tube Lock is misaligned it can cause issues in further installation steps. (56) Half thread M4 (3 Hex)
  • Page 17 Full thread M4 (3 Hex) (56)
  • Page 18 Tighten with pliers to secure water tightness. (56)
  • Page 19 (56)
  • Page 20 Make sure Smart Sensor Unit is inserted correctly. The O-ring should not be visible. (56)
  • Page 21 (56)
  • Page 22 (56)
  • Page 23 (56)
  • Page 24 (56)
  • Page 25 M8 Socket Head (56)
  • Page 26 Make sure to have correct alignment against thread. (56)
  • Page 27 (56) Electrical installation should be performed according to local regulations by a licensed electrician.
  • Page 28 Provided by client (56)
  • Page 29 (56)
  • Page 30 (56)
  • Page 31 (56)
  • Page 32 (56)
  • Page 33 (56) M3 (5.5mm driver) Mount Indo Panel.
  • Page 34 (56) Make sure the gasket is placed in the circular groove.
  • Page 35 (56)
  • Page 36 M4 Hex (2,5 mm) (56)
  • Page 37 (56)
  • Page 38 Make sure to have correct alignment against thread. (56)
  • Page 39 (56)
  • Page 40 (56)
  • Page 41 (56)
  • Page 42 (56)
  • Page 43 Adjust Secure (56) M3 nut M3 nut Adjust Indo Panel angle.
  • Page 44 (56) Adjust Indo Panel depth.
  • Page 45 Shower Unit installed Next step: Installing the Shower Head (56)
  • Page 46 I N S TA L L I N G T H E S H O W E R H E A D (56)
  • Page 47 C O M P O N E N T O V E R V I E W Shower Head Arm Shower Head Shower Water Connector Wall Mount Disc (56) Shower Head Wall Mount...
  • Page 48 (56) 2 mm It is recommended to cut the Angle Wall Box with the LK Wall Box Cutter UNI.
  • Page 49 (56) Cover both ends of the Shower Water Connector with teflon tape to avoid leakage.
  • Page 50 Screw the Shower Head Wall Mount flush to the wall or leakage may occur. (56)
  • Page 51 Apply lubricant to PEX Hose inside of Shower Head Arm. (56)
  • Page 52 Shower Head installation completed. (56)
  • Page 53 N E X T S T E P The shower will not function without executing following steps. See “Oas Indo Manual” or “Oas Indo Operation & Maintenance Manual” Insert Quartz Glass as instructed in the second half of the chapter “Cleaning the Quartz Glass”.
  • Page 54 I N S TA L L I N G T H E H A N D S H O W E R (56)
  • Page 55 C O M P O N E N T O V E R V I E W Hand Shower Shower Hose (56)
  • Page 56 (56)
  • Page 57 C E R T I F I E D S P A C E T E C H N O L O G Y...