Orbital Systems OS8732-Ei2 User Manual

Orbital shower
Hide thumbs Also See for OS8732-Ei2:

Advertisement

Quick Links

User Guide
Orbital Shower (OS8732-Ei2, OS8733-E)
5-06-0006
Publication date 2023-10-12

Advertisement

Table of Contents
loading

Summary of Contents for Orbital Systems OS8732-Ei2

  • Page 1 User Guide Orbital Shower (OS8732-Ei2, OS8733-E) 5-06-0006 Publication date 2023-10-12...
  • Page 2 All rights reserved. No part of this document may be reproduced or copied in any form or by any means without written permission from Orbital Systems. The English language version of this document contains the original instructions. All other language versions are translations of the original instructions.
  • Page 3: Table Of Contents

    Table of Contents Thank you for your purchase ......................4 EU Declaration of Conformity ......................5 Prerequisites and Approvals ......................6 Service ..........................6 Shower Activation, Wi-Fi Setup and Installation test ................. 7 Operating the Orbital Shower ......................8 Start and Stop Shower ......................8 Adjust Temperature .......................
  • Page 4: Thank You For Your Purchase

    Do not discard this manual, keep it handy for future reference. This manual is valid for all shower models. When applicable the manual will only be displaying the Orbital Systems Shower Head & Hand Shower variant. Page 4 of 24...
  • Page 5: Eu Declaration Of Conformity

    The product has undergone mandatory or voluntary certification procedures in order to receive the following certificates: KIWA 1513 KIWA K100686/02 TGA Nr. TGA.2023/005 DVGW W 540 CERT AS-0605DO0262 RiSE C900374 Nemko P23226975 RiSE C900373 KIWA 0753 Signed for and on behalf of Orbital Systems AB Place Date Name Position Malmö 2023-09-26 Mehrdad Mahdjoubi 5-01-0005_B The manufacture of this product has been made in accordance with the Type-approved decision on production control and the documents submitted to the decision of issue of this certificate.
  • Page 6: Prerequisites And Approvals

    Orbital Shower is designed and type approved according to the Swedish requirements in Swedish National Board Orbital Systems and our team of expert staff are available of Housing and Building & Planning regulations (BBR). to assist you if you require product advice, experience any...
  • Page 7: Shower Activation, Wi-Fi Setup And Installation Test

    Shower Activation, Wi-Fi Setup and Installation test To set up Wi-Fi and do an installation test on your Orbital Shower, please download My Water by Orbital Systems from App Store or Google Play and follow the instructions provided in the app.
  • Page 8: Operating The Orbital Shower

    Operating the Orbital Shower Start and Stop Shower Adjust Temperature Tap to start and stop the Shower. The Orbital Shower performs a short startup sequence to fill up the system and adjust water temperature before water starts pouring out of the shower head. Similarly, after the shower session, it also performs an Express cleaning sequence to empty and prepare the system for the next user.
  • Page 9: Shower Menu

    Shower Menu Shower Menu Features The shower menu will contain a slightly varying set of features depending on which shower profile your shower is Long press to access the shower menu. set to (for example 'home' or 'business' profile). To read more and manage shower profiles please visit the shower settings in My Water.
  • Page 10: Switch Between Shower Head And Hand Shower

    Switch between Shower Head and Hand Moon mode shower Activating ‘Moon mode' will further increase savings, by allowing slight variations in water flow and temperature. ‘Moon mode’ can be activated or deactivated from the shower menu, or set as default in My Water. Page 10 of 24...
  • Page 11: Pair Your Device With Orbital Audio

    Pair your device with Orbital Audio You find the name and PIN to your Orbital Audio on the amplifier. The placement of the amplifier depends on your Check the name and PIN on the amplifier. installation model: Basic The amplifier is mounted on the wall, next to the shower core.
  • Page 12: Automated Cleaning

    Automated Cleaning Procedure Description Duration Express cleaning Automatically cleans the Orbital Shower Core after each shower to ~ 3-4 min. prepare for the next session. Deep cleaning Is done automatically once a day at a preset time (can be set in ~ 6-7 min.
  • Page 13: Maintenance

    Maintenance Follow the cleaning and maintenance instructions in this manual to maximize the shower's lifespan and performance. The Orbital Shower uses a number of consumable components that will require periodic replacement to ensure optimal performance throughout the product’s lifespan. Consumable components are not covered by the warranty. The frequency of consumable replacement depends on a number of factors including usage, water quality, contamination levels and the adherence to regular maintenance and cleaning procedures outlined in this manual.
  • Page 14: Maintenance Overview & Notifications

    Maintenance Overview & Notifications Maintenance procedure When to perform Estimated time Consumables needed to perform Perform when the ~15 s Filter Capsule: Replace when Maintenance icon is shown depleted. This consumable is on the Control Dial or in included in the Orbital Care My water.
  • Page 15: Change The Filter Capsule

    Change the Filter Capsule • Filter Capsule Model No: OS C1050085A10 Model Cabinet/Hatch: Access Orbital Shower • Use only Orbital Systems Filter Capsule OS C1050085A10 Core in the Shower System • Spare Part Reference: 1-05-0085 Filter Capsule Icon shown on Control Dial Screen when Filter Capsule change is needed.
  • Page 16 Insert new Filter Capsule. RISK OF LEAKAGE Make sure Filter Capsule is inserted all the way in or leakage may occur. "Click!" Page 16 of 24...
  • Page 17: Descale

    The active chemical ingredients in the Descaling Tablets are fully biodegradable and environmentally friendly. The chemicals are food-safe and typically used for descaling coffee machines. Orbital Systems still recommends not to ingest the Descaling Tablets or the water during a Descaling procedure.
  • Page 18 Descaling is completed. Page 18 of 24...
  • Page 19: Clean The Drain

    Sensor Tank is cleaned. Failing to maintain the Recirculation Mesh may lead to clogging which will affect the ability to recirculate water. Please contact Orbital Systems if Recirculation Mesh needs to be replaced. Page 19 of 24...
  • Page 20 Use non-abrasive cleaning agents only. Make sure to clean all surfaces of each component, including the Drain Unit. NOTICE Make sure the O-ring is correctly mounted before reassembly of Sensor Tank. Page 20 of 24...
  • Page 21 Insert Sensor Tank. NOTICE Place the Funnel with the hole oriented to the left! Placing the hole oriented to the right will disable recirculation. CAUTION Make sure Sensor Tank is inserted correctly. The edge of the Sensor Tank should be fully pushed towards the edge of the Drain Unit.
  • Page 22: Clean The Uv Filter

    Clean the UV Filter Icon shown on Control Dial Screen when UV Filter service is needed. Start with running a Descale to remove any limescale deposits from the UV Filter. For more details see Chapter Descale [17]. If the system is still signaling that the UV Filter needs to be cleaned after the Descaling has been completed, please contact Orbital Support.
  • Page 23: Long Periods Of Shower Inactivity

    Long Periods of Shower Inactivity We recommend that the Orbital Shower always remain connected to electricity and water supply to allow it to continuously run automated cleaning and maintenance procedures. If the shower has to be disconnected from electricity and/or water for long periods of time (more than a week of inactivity) we recommend running a Descale (see Chapter Descale [17]...