OPERATING INSTRUCTIONS

Safety Precautions

WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts such
as output terminals or internal wiring.
• Unless using cold feed feature when inch-
ing with gun trigger, electrode and drive mech-
anism are "hot" to work and ground and could
remain energized several seconds after the
gun trigger is released.
• Turn OFF input power at welding power
source before Control switch setup or
changing drive roll and/or guide tubes.
• Welding power source must be connected
to system ground per the National
Electrical Code or any applicable local
codes.
• Only qualified personnel should
operate this Equipment.
Observe all additional Safety Guidelines detailed
throughout this manual.

Duty Cycle

The DH-10 models are rated at 60% duty cycle * for a
maximum current of 600 amps.
* Based on a 10 minute time period (6 minutes on, and 4 minutes off).
DH-10 CONTROL SWITCH SETUP
Initial set up of the DH-10 control for the system com-
ponents being used and for general operator prefer-
ences is done using a pair of 8-pole DIP switches
located inside the DH-10 control box.
Setup DIP Switch Access
1) Shut off the input power to the DH-10 control by
turning off the power at the welding power source
it is connected to.
2) Remove the two screws on the top of the DH-10
control box door and swing the door down to
open.
3) Locate the two 8-pole DIP switches, near the top
left corner of the DH-10 Control P.C. board,
labeled S1 and S2.
4) Switch settings are only programmed during input
power-up restoration.

OPERATION

Setting the DIP Switches
The DIP switches are each labeled with an "ON"
arrow showing the on direction for each of the 8 indi-
vidual switches in each DIP switch (S1 and S2). The
functions of these switches are also labeled and set
as described below:
Pwr Sources
ON
1
2
3
4
S1
Wire Drive Head Selection
The DH-10 control is set up for proper presettable
wire feed speed by setting S2 DIP switches (1 to 4) for
Head 1 (left side head) and DIP switches (5 to 8) for
Head 2 (right side head) as appropriate per the follow-
ing examples for the head specification and DH drive
external gear selection being used:
NOTE: Set the proper 4 switches labelled for Head 1
(Left Head) or Head 2 (Right Head) as appropriate for
the way that Head is being used.
DH-10 HEADS:
For K1497-1,-3 (DH-10 Boom) or K1499-1, -3 (DH-
10 Bench) with 35-500 IPM (0.89-12.7 m/m) Low
Speed Ratio set S2 DIP Switches as follows:
For K1497-1,-3 (DH-10 Boom) or K1499-1, -3 (DH-
10 Bench) with 50-750 IPM (1.25-19.0 m/m) High
Speed Ratio set S2 DIP Switch as follows: (initial
factory setting)
For K1497-2,-4 (DH-10 Boom) or K1499-2, -4 (DH-
10 Bench) with Left Head 35-500 IPM (0.89-12.7
m/m) & Right Head 55-825 IPM (1.40-21.0 m/m)
Low Speed Ratio set S2 DIP Switch as follows:
For K1497-2,-4 (DH-10 Boom) or K1499-2, -4 (DH-
10 Bench) with Left Head 50-750 IPM (1.25-19.0
m/m) & Right Head 80-1250 IPM (2.00-31.8 m/m)
High Speed Ratio set S2 DIP Switch as follows: (ini-
tial factory setting)
DH-10
Security
HEAD 1
M 4
S1
ON
5
6
7
8
1
2
3
S2
HEAD 2
HEAD 1
S2
ON
1
2
3
4
5
6
7
8
S2
HEAD 2
HEAD 1
S2
ON
1
2
3
4
5
6
7
8
S2
HEAD 1
HEAD 2
S2
ON
1
2
3
4
5
6
7
8
S2
HEAD 1
HEAD 2
S2
ON
1
2
3
4
5
6
7
8
S2
B-1
HEAD 2
S2
4
5
6
7
8

Advertisement

Table of Contents
loading

Table of Contents