Advertisement

Quick Links

CRESSIDA HE GAS FIRE
USER INSTRUCTIONS
INSTALLATION INSTRUCTIONS
SERVICE INSTRUCTIONS
It is a regula on that these instruc ons be handed to the customer a er installa on is complete. It is
also the responsibility of the installa on engineer to ensure that the customer is able to fully operate
the appliance and is aware of any cleaning or maintenance requirements.
This product is not suitable for primary hea ng purposes.
Model numbers: F-0510X1 MANUAL for use on Natural Gas (G20) at a supply pressure of 20 mbar in GB/IE
Model numbers: F-0510X2 SLIDE for use on Natural Gas (G20) at a supply pressure of 20 mbar in GB/IE
(X denotes trim type)
P-XX1540 ISSUE 11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F-0510 1 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Wildfire F-0510 1 Series

  • Page 1 CRESSIDA HE GAS FIRE USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS It is a regula on that these instruc ons be handed to the customer a er installa on is complete. It is also the responsibility of the installa on engineer to ensure that the customer is able to fully operate the appliance and is aware of any cleaning or maintenance requirements.
  • Page 2: Table Of Contents

    CONTENTS Regulatory Informa on and Installa on Requirements …………………………... 3 Installa on Requirements (con nued) ………………………………………………….. 4 Si ng the Appliance ……………………………………………………………………………… 5 Fixing the Appliance ...………………………………………………………………………...… 7 Front glass removal and replacement ……………………………………………………. 8 Connec ng the Appliance to the Gas Supply ……………………………………….. 9 Checking Opera on of Appliance …………………………………………………………...
  • Page 3: Regulatory Informa On And Installa On Requirements

    REGULATORY INFORMATION AND INSTALLATION REQUIREMENTS THE FOLLOWING MUST BE NOTED PRIOR TO THE INSTALLATION OF THIS APPLIANCE. This gas appliance MUST be installed by a GAS SAFE registered installer by law. It must be installed in accordance to these installa on instruc ons and the GAS SAFETY (Installa on & Use) REGULATIONS 1998 as amended.
  • Page 4: Installa On Requirements (Con Nued)

    No purpose made ven la on is normally required for this appliance when installed in G.B. If the appliance is being installed in I.E then refer to I.S 813:1996 (Domes c Gas Installa on—Na onal Standards Authority of Ireland). Ven la on areas (if applicable) should be checked periodically to ensure there is no obstruc on, even though none is normally required for this appliance.
  • Page 5: Si Ng The Appliance

    SITING THE APPLIANCE Fireplace Opening This fire is suitable for fi ng to non-combus ble fireplace back panels with a temperature ra ng of at least 150 . (This is also known as CLASS”O” - If in doubt please contact the supplier of the back panel supplier to check suitability.
  • Page 6 Fireplace Opening (Hole in the Wall Installa on) This appliance MUST be installed in accordance with all relevant sec ons of document ‘J’ of the building regula ons. This appliance may be installed such that the base of the appliance sit on the surface of a fireplace opening at least 110mm up from the floor—this dimension ensures that there is no incandescent material (flame or ceramic impinged by flame) is less than 225mm from the floor.—This is a requirement of document ‘J’of the building regula ons.
  • Page 7: Fixing The Appliance

    Fixing the Appliance. If the appliance is being installed with a spacer kit, this should be a ached to the appliance using the screws included and the foam seal which is supplied with the appliance should be affixed to the rear face of the spacer. Do not use any permanent sealing substance as this will invalidate warranty as the appliance cannot be removed for periodical inspec ons.
  • Page 8: Front Glass Removal And Replacement

    Removal of the front glass panel. The top glass clamp is held in place with 3 screws. This panel is concealed behind the top cover strip which is held in place by two magnets. The two magnets are fi ed to the top glass clamp as shown in this diagram.
  • Page 9: Connec Ng The Appliance To The Gas Supply

    Connec ng the Appliance to the Gas Supply The gas supply can be connected to the appliance by a concealed fi ng from the rear. In all installa on condi ons the gas connec on should be provided using 8mm (O/D) copper tubing. If the concealed installa on method is chosen, there are three op onal entry points at the rear/side of the appliance.
  • Page 10: Comple Ng The Installa On

    Comple ng the Installa on of the Appliance Remove the protec ve covering (if applicable) from the face of the decora ve trim. Fit the trim to the appliance with the magnets provided. One magnet should be placed in each corner of the trim at the top of the appliance and on each side about 120mm from the base of the appliance.
  • Page 11: Appliance Technical Informa On

    Maintenance of the Appliance The following procedures can and should be performed by the customer at regular intervals depending upon use of the appliance. Appliance Technical Informa on Gas Type : Natural Gas Category : I2H Inlet Pressure: (Cold) 20mbar Heat Input Gross : 5.3kW Injector : 072 Des na on Countries : GB...
  • Page 12: Service Instruc Ons

    Cleaning the Appliance (con nued) Trim, Fret and Painted Metal Parts There are a variety of trim and fret op ons which may have been supplied with your appliance and these are normally a plated material on a steel substrate. It is important that no abrasive cleaners or chemical agents are used in the cleaning of these components.
  • Page 13 Removal / Replacement of Gas Carrying Components (con nued) Manual Control Valve Remove the control knob from the valve. Remove the locknut from the front of the valve. Undo the three nuts around the periphery of the valve body—Gas Inlet / Burner / Pilot Remove the thermocouple nut from the back of the valve.
  • Page 14: User Instruc Ons

    OPERATING INSTRUCTIONS This appliance is available with two opera ng methods, namely manual control and slide control. The following instruc ons detail both methods of opera on however the basic opera on of the appliance involves the igni on of a pilot burner (See page 7 for spillage monitoring details—ODS), then the control of the main burner with LOW and HIGH se ngs.
  • Page 15: Coal Layout Instruc Ons

    FUEL BED LAYOUT (COAL) The following instruc ons detail how the ceramic fuel bed and loose components are to be installed onto the appliance. Great care should be taken when handling these ceramic parts as they are fragile and can easily be broken.
  • Page 16 Step 4 Fit the coal piece B shown in the picture below. The arrow should point towards the back of the fire. Ensure this coal B sits on the front rail ledge and is supported by coal A on the le . This coal sits in an almost ver cal posi on.
  • Page 17 Step 6 Fit the coal piece D shown in the picture below. The arrow should point towards the back of the fire. Step 7 Finally fit the last two loose coals at the back of the fire as shown in the picture below.
  • Page 18: Product Fiche

    Product Fiche Manufacturer : Hearth Products Ltd Model No. F-051XX1 F-051XX2 Fuel Type Natural Gas I2H Natural Gas I2H Energy Efficiency Class Indirect Hea ng Func onality Direct Heat Output kW 4.2kW 4.2kW Indirect Heat Output kW Useful Energy Efficiency (NCV) High : 87.2% High : 87.2% Useful Energy Efficiency (NCV)
  • Page 19: Spare Parts List

    User Replaceable Parts Part Number Descrip on P-XX11601 Ceramic Rear Fuel Bed-Coal and Coals P-XX11611 Ceramic Front Fuel Bed P-XX1380 Glass Panel (Silk Screened) To order spare parts for your appliance visit www.hearthproducts.co.uk/sparesshop or call us directly on 01785 225401 It is important to note that the above spares are user serviceable components that can be changed by the customer.