Si34-601A
Model Name (Combination Unit)
Model Name (Independent Unit)
1 Cooling Capacity (19.5°CWB)
2 Cooling Capacity (19.0°CWB)
3 Heating Capacity
Casing Color
Dimensions: (H×W×D)
Heat Exchanger
Type
Piston Displacement
Number of Revolutions
Comp.
Motor Output×Number
of Units
Starting Method
Type
Motor Output
Fan
Air Flow Rate
Drive
Liquid Pipe
Connecting
Pipes
Gas Pipe
Product Mass (Machine Weight)
Safety Devices
Defrost Method
Capacity Control
Refrigerant Name
Refrigerant
Charge
Control
Refrigerator Oil
Standard Accessories
Drawing No.
Notes:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5m, level difference
4 The units with anti-corrosion treatment will be available as standard. Please specify the suffix "E" as
Specifications
RXYQ50PY1(E)
RXYQ14PY1(E)+RXYQ18PY1(E)+RXYQ18PY1(E)
kcal / h
Btu / h
kW
kW
kcal / h
Btu / h
kW
Ivory White (5Y7.5/1)
mm
(1680×1240×765)+(1680×1240×765)+(1680×1240×765)
Cross Fin Coil
Hermetically Sealed Scroll Type
m³/h
(13.72+10.53+10.53)+(13.72+10.53+10.53)+(13.72+10.53+10.53) (13.72+10.53+10.53)+(13.72+10.53+10.53)+(13.72+10.53+10.53)
r.p.m
(6300, 2900×2)+(7980, 2900, 2900)+(7980, 2900, 2900)
kW
((0.3+4.5+4.5)×1)+((3.0+4.5+4.5)×1)+((3.0+4.5+4.5)×1)
Propeller Fan
kW
(0.35×2)+(0.75×2)+(0.75×2)
m³/min
233+239+239
Direct Drive
φ
mm
19.1 (Brazing Connection)
φ
mm
41.3 (Brazing Connection)
kg
329+341+341
High Pressure Switch, Fan Driver Overload Protector, Over
Current Relay, Inverter Overload Protector
%
kg
12.3+12.7+12.7
Electronic Expansion Valve
Refer to the nameplate of compressor
Installation Manual, Operation Manual, Connection Pipes,
Clamps
difference : 0m.
difference : 0m.
: 0m.
RXYQ5PY1E.
120,000
474,000
139
138
136,000
539,000
158
Soft Start
High Pressure Switch, Fan Driver Overload Protector, Over
Current Relay, Inverter Overload Protector
Deicer
3~100
R-410A
Installation Manual, Operation Manual, Connection Pipes,
Clamps
RXYQ52PY1(E)
RXYQ16PY1(E)+RXYQ18PY1(E)+RXYQ18PY1(E)
124,000
491,000
144
143
140,000
556,000
163
Ivory White (5Y7.5/1)
(1680×1240×765)+(1680×1240×765)+(1680×1240×765)
Cross Fin Coil
Hermetically Sealed Scroll Type
(6300, 2900×2)+(7980, 2900, 2900)+(7980, 2900, 2900)
((1.4+4.5+4.5)×1)+((3.0+4.5+4.5)×1)+((3.0+4.5+4.5)×1)
Soft Start
Propeller Fan
(0.35×2)+(0.75×2)+(0.75×2)
233+239+239
Direct Drive
φ
19.1 (Brazing Connection)
φ
41.3 (Brazing Connection)
329+341+341
Deicer
3~100
R-410A
12.5+12.7+12.7
Electronic Expansion Valve
Refer to the nameplate of compressor
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
Specifications