4.1.5

Operating modes (functional sequences)

4.1.5.1

Explanation of symbols

Symbol
Meaning
Press torch trigger 1
Release torch trigger 1
Current
I
Time
t
Gas pre-flow
Ignition current
Up-slope time
Spot time
Main current (minimum to maximum current)
AMP
Secondary current
AMP%
Pulse time
Pulse pause time
Down-slope time
End-crater current
Gas post-flow
Balance
Frequency
099-00T402-EW501
24.04.2018
Functional characteristics
TIG welding