Rangehood Installation - Belling BPC90BR Instruction Manual

Pyramid & t-shape canopy rangehoods
Table of Contents

Advertisement

1. SAFETY INSTRUCTIONS
INSTALLATION
1.1 General Safety Warnings
1. SAFETY INSTRUCTIONS

RANGEHOOD INSTALLATION

Check the area where the range hood is to
1.1 General Safety Warnings
be fitted, to ensure that it is structurally sound
1. SAFETY INSTRUCTIONS
and will support the weight of the appliance.
If installing into plasterboard, ensure a suitable
WARNING:
anchor is used and not just standard screws.
1.1 General Safety Warnings
The best method of installation is for the
rangehood to be fixed into studs or noggins in the
Icon
WARNING:
wall to ensure it is secure and minimize vibration.
Type
For various installation types, use screws
WARNING
WARNING:
RISK OF ELECTRIC SHOCK
and screw anchors suited to the type of wall
RISK OF ELECTRIC SHOCK
SYMBOL ISO 7010 W021
(e.g. reinforced concrete, plasterboard, etc.).
WARNING:
SYMBOL ISO 7010 W021
WARNING: always check that the
WARNING:
WARNING:
CAUTION
WARNING:
IMPORTANT / NOTE
screws and screw anchors provided
IMPORTANT / NOTE
with the product are suitable for the type
of wall on which the hood is to be fixed.
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
x
x
y
y
Type
WARNING
CAUTION
EN - 2
EN - 4
Figure 1
EN - 4
EN - 4
1. Locate the position and height of where
the mounting bracket will be fixed to.
This will be a combination of the distance between
the bottom of the rangehood and the cooktop (y)
and the distance from the base of the rangehood
to the screw holes on the wall bracket when placed
on the back of the rangehood (x), figure 1.
2. Secure the wall bracket to the wall at two
Meaning
(2) points using suitable anchors and screws
Meaning
Serious injury or death risk
and mount the flue extension bracket directly
Serious injury or death risk
above at the very top of the wall, figure 2.
Dangerous voltage risk
Use a spirit level to check alignment,
Dangerous voltage risk
both vertically and horizontally.
3. Directly above the flue extension bracket, cut a
155mm diameter hole in the ceiling for ducting
to pass through. The edge of the hole should start
EN - 2
no further than 10mm away from the wall to ensure
it is covered by the flue extension, once in place.
4. Feed 150mm ducting down through the hole
in the ceiling and leave loose until ready to
connect to the outlet on the rangehood.
Flue
Flue
Extension
Extension
Bracket
Bracket
Wall
Wall
Bracket
Bracket
12
Figure 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Btc90bgBtc110bg