Table 5-2: Mode Select Command Field Values

Field Location
Field Name
Byte
PF
01
SP
01
(Save Pages)
Parameter List
04
Length
Mode Parameter Lists
Following the command block, in the data out phase, the initiator sends a parameter
list containing the new parameter values of the library. This parameter list has the
same format as the data the library returns to a MODE SENSE command, with the restriction
that only one type of mode page per command is allowed for MODE SELECT. See the MODE
SENSE chapter for detailed descriptions of all mode parameters.
The following restrictions apply when reassigning element addresses:
• Element addresses must not overlap
• Element groups (i.e. cartridge slots, picker, drives) must be assigned contiguous
addresses
• Element addresses must be between 0 and 65,535
Chapter 5. Mode Select—15h
Values
Meaning
Allowed
Bit
4
1
The library supports the page format defined by the SCSI-2 standard.
Mode pages are not saved. Mode parameter changes requested in
0
0
1
The value of this byte represents the length of the entire parameter
list. When the value of the parameter list length is 00h, no parameter
list is transferred from the initiator. This is not considered an error.
All
00-FFh
You might send a MODE SELECT command with no parameter list
and the SP bit set to 1, for example, to force the library to save its
the parameter list are still made.
All mode pages are saved, whether they are changed in this
command or not.
current mode page settings without changing them.