Page 1
PPC-200(W) Operation Manual PPC-200W: WASHDOWN PPC-200: SPLASH-PROOF Version 5.00 YAMATO CORPORATION YAMATO TECH CORPORATION 1775 S. Murray Blvd. #112-19425 Langley By-Pass Colorado Springs, CO 80916 USA Surrey, B.C. V3S 6K1 Canada Tel (719) 591-1500 Fax (719) 591-1045 Tel (604) 533-2338 Fax (604) 533-0827...
Page 2
6) Do not disassemble or modify the scale, you will void the warranty. Modified scales will not be legal for trade. 7) The PPC-200 is not a washdown scale, it is splash-proof. Do not use a water sprayer on the PPC-200 and do not use it in an extremely humid or dusty environment.
PPC-200(W) Operation Manual Table of Contents Name and Function of Parts Specifications III. Directions for Use A. Installing Batteries or AC Adaptor B. Levelling the Scale C. Turning the Scale On and Off D. Checking the Battery Level E. Zero the Display F.
PPC-200(W) Operation Manual I Name and Function of Parts Fig. 1: Front side of the scale Fig. 2: Bottom of the scale ON/ZERO Key Turns the power on, and zeroes the display. OFF Key Turns the power off. TARE Key Tares off the weight on the scale platform.
PPC-200(W) Operation Manual III Directions for Use III.A Installing Batteries or AC adaptor Remove the stainless steel platform. Gently and carefully turn the scale on it's side. Ensure the surface around the battery cover is dry. Do not allow water to enter the battery compartment. Turn the bat- tery cover thumbscrew counterclockwise until it comes free.
PPC-200(W) Operation Manual III Directions for Use III.G Setting the Over/Under Indicator 1) Place the scale in normal weighing mode. 2) Press and hold the key and push the key. (Yellow Cor- ners) 3) Press the key to select the digit you want to change. The underscore will advance to the right.
PPC-200(W) Operation Manual III Directions for Use III.H Weighing III.H.1 Using the Under/Over Indicator 1) Begin with no load on the scale, the display reading zero, and the center zero and stable indicators lit. The small up and down arrowheads on the right side of the display indicate that the over and under setpoints, respectively, have been set.
PPC-200(W) Operation Manual III Directions for Use III.H Weighing III.H.3 Net Weighing 1) Begin with no load on the scale, the display reading zero, and the center zero and stable indicators lit. 2) Place an empty container on the scale platform and press the key.
PPC-200(W) Operation Manual III Directions for Use III.H Weighing III.H.4 Batching (continued) 5) Continue in this manner until all items to be batched have been weighed. Do not allow the gross weight on the scale platform to exceed the capacity of the scale.
Page 10
PPC-200(W) Operation Manual IV Entering User Parameter Mode 3. To change a parameter value, use the keys as follows: - increase value by one - increase value by ten - decrease value by one - decrease value by ten 4. Press...
PPC-200(W) Operation Manual V Optional Analog Meter * * * WARNING * * * The PPC-200W is NOT WASHDOWN if the analog meter has been installed! Damage will result to the scale and meter if an attempt is made to washdown the scale after it has been modified for the analog meter.
Page 12
PPC-200(W) Operation Manual V Optional Analog Meter Setting the Analog Meter 1) Press and hold the key for 2-3 seconds. The display will show the current under setpoint. 2) Press the key to select the digit you want to change.
PPC-200(W) Operation Manual VI Troubleshooting and Error Messages The scale can check various functions automatically. When a problem is detected, the following mes- sages will be displayed. If you take the steps described below but the problem is not fixed, the scale needs to be serviced by a qualified scale technician.
The RS-232 serial interface option is only available and legal-for-trade on CPU versions 4.02 and above. See section 4 (Changing the Scale Setup - Test Mode) of the PPC-200(W) Technical Manual for instructions on how to enter test mode and view the CPU version. See the PPC RS232 Operation Manual for more information on using the RS-232 serial interface option.