Cadel Venus Plus Instructions For Installation, Use And Maintenance Manual page 35

Table of Contents

Advertisement

Available languages

Available languages

PROBLEM
CAUSE
Stove without
power supply
Burned board
protection fuse
Control display
Faulty control
does not ignite
display
Faulty flat cable
Faulty mother
board
Empty hopper
Auger blocked by
a foreign object
Pellet does
(for example nails)
not reach the
combustion
Auger
chamber
motorreducer out
of order
Check on the
display if there is
an active alarm
"ACTIVE ALARM"
Empty hopper
Auger blocked by
a foreign object
(for example nails)
Fire extinguishes
Poor quality pellet
and stove stalls
Pellet loading
value too law
"phase 1"
Check if there is
an active alarm
"ACTIVE ALARM"
Running stove
Automatic
and display
burning pot
showing "BURN
cleaning
POT CLEAN"
VENUS PLUS - GIOIA-2
SOLUTION
Check if the plug is put in the socket.
Replace the board protection fuse (4A-250V).
Replace the control display.
Replace tha flat cable.
Replace the mother board.
Fill the hopper.
Clean the auger.
Replace the motorreducer.
Have the stove overhauled.
Fill the hopper.
Clean the auger.
Try with other pellet types.
Adjust pellet load.
Have the stove overhauled.
At idling stove and at maximum fume suction NO PROBLEM!
INTERVENTION
EN
35

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Gioia-2

Table of Contents