Operation Management

AREA SETTING

If confi gured with Area Setting and a certain input is selected as the trigger of entrances of confi gured [Area],
a corresponding input event will inform how many occupants are remaining in the area.
Area Setting [Add]
J
Using this function, managers can check remaining card holders in the specifi ed [Area] when the corresponding area
has an entrance reader and there were card input events for the reader. This function utilizes SAMS Pro and SAMS
Communication Server Pro, which may not operate properly if.
- there were too many events and the fi re event input was delayed for reception and processing
- the application operating PC is turned off or not properly operating
- communication between devices or its confi gurations are not properly set
- SAMS Pro or SAMS Communication Server Pro is not running
- Upon a fi re event, SAMS Pro will report all registered area's mustering report if card holders did not properly
conduct entering/exiting card readings. (An entrance assigned to one area cannot be assigned to another area.)
J
An entrance of mustering area must have entering/exiting readers.
1.
From the top menu bar, select [Operation Management] > [Area Setting].
2.
From the top tool bar, click Add <
3.
Enter the area name in [Area Name].
4.
Select the entrance to be opened on a fi re from the [Door List] and click <
Or you can use the drag-and-drop method for this purpose.
60_ Operation Management
>.