4
3
1
1
power button with status LED
2
RV-C ports
3
removable top lid for serviceability
4
optional brackets for easy mounting to a wall
5
handle clips in to keep it from flopping around
6
integrated screw holes for easy mounting
Easy mounting works well for width limited enclosures.
100Ah
Mount the battery on wall either in vertical or standing position with the screws and the mounting bracket.
Do not mount the battery on the wall without the mounting bracket.
Do not mount the battery on the wall with mounting bracket in horizontal position.
Maximum of 8 batteries can be connected in parallel.
Maximum of 4 batteries can be connected in series.

9 Configuration

1.
NOTICE! Damage Hazard
The embedded BMS in the battery is designed for maximum 4 pieces in serials use. Do not connect more than 4 pieces of battery in series.
The batteries communicate with each other using the RV-C ports to co-ordinate balancing. The master battery collects the information from the secondary batteries in the bank
and relays the information on behalf of the entire bank of up to 32 batteries via BLE and RV-C.
2
3
6
300 Ah
5
EN