Cleaning; Storage; Troubleshooting; Disposal - Dometic GP-ADV-LIFEPO4-100 Installation And Operating Manual

Hide thumbs Also See for GP-ADV-LIFEPO4-100:
Table of Contents

Advertisement

EN

10 Cleaning

The lithium batteries are maintenance-free. Occasionally clean the product with a damp cloth.

11 Storage

Battery is shipped in shutdown mode, and SOC is about 30 % by air shipment, about 50 % SOC by sea shipment. The storage environment requirement is as follows:
Storage Temperature range ℃ (At 50 % SOC in shutdown mode
and specified temp, recoverable capacity in % vs time/30 % )
Do a cycle test when the storage reaches 12 months in the warehouse (Based on the date of manufacture on the label). After that, the battery voltage to be checked every three
months. Battery Pack Voltage ≤12 V, need to do second cycle test. And after another year,do a cycle test.

12 Troubleshooting

Problem
Battery cannot discharge
Battery cannot charge
Mobile App cannot connect
RV read battery information fail

13 Disposal

Recycling products with batteries, rechargeable batteries and light sources: Remove any batteries, rechargeable batteries, and light sources before recycling the prod-
uct. Return defective or used batteries to your retailer or dispose of them at collection points. Do not dispose of any batteries, rechargeable batteries, and light sources with gener-
al household waste. If you wish to finally dispose of the product, ask your local recycling center or specialist dealer for details about how to do this in accordance with the applicable
disposal regulations. Do not disassemble and do not dispose of in fire.The product can be disposed free of charge.
Recycling packaging material: Place the packaging material in the appropriate recycling waste bins wherever possible.
12
-20 °C~25 °C < 18 months
25 °C~45 °C < 3 months
45 °C~60 °C < 1 month
20±5 °C is the recommended storage temperature
Possible cause
Protection against over-temperature (cell temperature is high-
er than 80 °C)
Protection against under voltage protection
Protection against over current protection
Battery output terminal is short circuit
System failure
Protection against over voltage protection
Protection against over current protection
Protection against over-temperature or under- temperature
(cell temperature is lower than 0 °C or higher than 60 °C)
Battery output terminal is short circuit
System failure
Poor signal
Battery pack is shutdown
RV system CAN1 120 ohm resistor is missed or damaged
Cable 1, 2 and 3 poor connection
Battery pack ID is not correct
Max. 80 % RH
Max. 80 % RH
Max. 80 % RH
Suggested remedy
Regulate battery pack discharge ambient temperature
lower than 55 °C
Charge battery
RV discharge power is over load, should decrease dis-
charge power.
Check the connection wire and try charge battery
Shutdown system and check the RV system function
Disconnect the charger and load discharge current for
few minutes.Try again to charge the battery.
Charge is abnormal and the output current is over value.
Regulate battery pack charge ambient temperature to
5 °C ... 45 °C. If charged in freezing weather, need to
wait until it is heated up to 5 °C by inner heater.
Check the connection wire and try charge the battery.
Check RV system and RV charger.
Approach RV system and try connect again.
Press physical button for 2 seconds to wake up battery
pack.
Check the Cable1 wire and RV system CAN1 port 120
ohm resistor.
Check cable 1,2 and 3 connection.
Check the battery ID setting and refer RV-C protocol to
correct battery pack ID one by one.
 